Door Elect Pass - 8T0 959 792 P

Coding for Door Elect Pass 8T0.959.792P on A4

8T0 959 792 P :H09 / :0305
Кодировка: 01  1C  12  20  5E  01  41  00  01 
label: 8K0-959-792.clb
Ошибки: 2
Byte 0 [01] / Binary: 00000001
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 1 [1C] / Binary: 00011100
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 2 [12] / Binary: 00010010
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 3 [20] / Binary: 00100000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 4 [5E] / Binary: 01011110
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 5 [01] / Binary: 00000001
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 6 [41] / Binary: 01000001
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 7 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 8 [01] / Binary: 00000001
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Address 52: Door Elect, Pass. (J387)       Labels:. 8K0-959-792.clb
   Part No SW: 8T0 959 792 P    HW: 8T0 959 792 G
   Component: TSG BF        H09 0305
   Revision: --------    Serial number: --------------
   Coding: 011C12205E01410001
   Shop #: WSC 06325 000 00000
   VCID: 55F34DDC25061A422C5-8000
 
2 Faults Found:
01482 - Motors for Central Locking
            007 - Short to Ground
             Freeze Frame:
                    Fault Status: 01100111
                    Fault Priority: 3
                    Fault Frequency: 96
                    Reset counter: 247
                    Mileage: 159544 km
                    Time Indication: 0
                    Date: 2023.01.02
                    Time: 16:14:39
 
02115 - Locking Unit for Central Locking
            008 - Implausible Signal
             Freeze Frame:
                    Fault Status: 01101000
                    Fault Priority: 3
                    Fault Frequency: 6
                    Reset counter: 159
                    Mileage: 159545 km
                    Time Indication: 0
                    Date: 2023.01.06
                    Time: 13:31:11