CAN Gateway - 7N0 907 530
Coding for CAN Gateway 7N0.907.530 on Superb II
7N0 907 530
:H27 /
:5603
Кодировка: ED A1 FF 06 00 06 02 00 00 33 03
Кодировка: ED A1 FF 06 00 06 02 00 00 33 03
label:
7N0-907-530-V1.clb
- Показать полный лог #61 for Superb II 2010 (19 control modules, scanned at 24.09.2020)
- Показать больше логов for Skoda Superb II 2010
- Показать больше элементов 7N0.907.530
Ошибки: 3
Fault 00457: Central Electronics Control Module / BCM (J519)
: No Signal/Communication
: No Signal/Communication
Fault 01330: Central Control Module for Central Convenience (J393)
: No Signal/Communication
: No Signal/Communication
Fault 01303: Telephone Transceiver (R36)
: No Signal/Communication
: No Signal/Communication
| Byte 0
[ED]
/ Binary: 11101101 |
|
|---|---|
| ☑ bit 0 | |
| ☐ bit 1 | |
| ☑ bit 2 | |
| ☑ bit 3 | |
| ☐ bit 4 | |
| ☑ bit 5 | |
| ☑ bit 6 | |
| ☑ bit 7 | |
| Byte 1
[A1]
/ Binary: 10100001 |
|
|---|---|
| ☑ bit 0 | |
| ☐ bit 1 | |
| ☐ bit 2 | |
| ☐ bit 3 | |
| ☐ bit 4 | |
| ☑ bit 5 | |
| ☐ bit 6 | |
| ☑ bit 7 | |
| Byte 2
[FF]
/ Binary: 11111111 |
|
|---|---|
| ☑ bit 0 | |
| ☑ bit 1 | |
| ☑ bit 2 | |
| ☑ bit 3 | |
| ☑ bit 4 | |
| ☑ bit 5 | |
| ☑ bit 6 | |
| ☑ bit 7 | |
| Byte 3
[06]
/ Binary: 00000110 |
|
|---|---|
| ☐ bit 0 | |
| ☑ bit 1 | |
| ☑ bit 2 | |
| ☐ bit 3 | |
| ☐ bit 4 | |
| ☐ bit 5 | |
| ☐ bit 6 | |
| ☐ bit 7 | |
| Byte 4
[00]
/ Binary: 00000000 |
|
|---|---|
| ☐ bit 0 | |
| ☐ bit 1 | |
| ☐ bit 2 | |
| ☐ bit 3 | |
| ☐ bit 4 | |
| ☐ bit 5 | |
| ☐ bit 6 | |
| ☐ bit 7 | |
| Byte 5
[06]
/ Binary: 00000110 |
|
|---|---|
| ☐ bit 0 | |
| ☑ bit 1 | |
| ☑ bit 2 | |
| ☐ bit 3 | |
| ☐ bit 4 | |
| ☐ bit 5 | |
| ☐ bit 6 | |
| ☐ bit 7 | |
| Byte 6
[02]
/ Binary: 00000010 |
|
|---|---|
| ☐ bit 0 | |
| ☑ bit 1 | |
| ☐ bit 2 | |
| ☐ bit 3 | |
| ☐ bit 4 | |
| ☐ bit 5 | |
| ☐ bit 6 | |
| ☐ bit 7 | |
| Byte 7
[00]
/ Binary: 00000000 |
|
|---|---|
| ☐ bit 0 | |
| ☐ bit 1 | |
| ☐ bit 2 | |
| ☐ bit 3 | |
| ☐ bit 4 | |
| ☐ bit 5 | |
| ☐ bit 6 | |
| ☐ bit 7 | |
| Byte 8
[00]
/ Binary: 00000000 |
|
|---|---|
| ☐ bit 0 | |
| ☐ bit 1 | |
| ☐ bit 2 | |
| ☐ bit 3 | |
| ☐ bit 4 | |
| ☐ bit 5 | |
| ☐ bit 6 | |
| ☐ bit 7 | |
| Byte 9
[33]
/ Binary: 00110011 |
|
|---|---|
| ☑ bit 0 | |
| ☑ bit 1 | |
| ☐ bit 2 | |
| ☐ bit 3 | |
| ☑ bit 4 | |
| ☑ bit 5 | |
| ☐ bit 6 | |
| ☐ bit 7 | |
| Byte 10
[03]
/ Binary: 00000011 |
|
|---|---|
| ☑ bit 0 | |
| ☑ bit 1 | |
| ☐ bit 2 | |
| ☐ bit 3 | |
| ☐ bit 4 | |
| ☐ bit 5 | |
| ☐ bit 6 | |
| ☐ bit 7 | |
Address 19: CAN Gateway Labels:. 7N0-907-530-V1.clb
Part No SW: 7N0 907 530 HW: 1K0 907 951
Component: J533 Gateway H27 5603
Revision: H27 Serial number: 150710F1000140
Coding: EDA1FF0600060200003303
Shop #: WSC 33361 790 00999
VCID: 6D87CB9DA19EEDEF11F-8038
3 Faults Found:
00457 - Central Electronics Control Module / BCM (J519)
004 - No Signal/Communication - Intermittent
Freeze Frame:
Fault Status: 00110100
Fault Priority: 2
Fault Frequency: 2
Reset counter: 67
Mileage: 57755 km
Time Indication: 0
Date: 2015.02.15
Time: 00:03:41
01330 - Central Control Module for Central Convenience (J393)
004 - No Signal/Communication - Intermittent
Freeze Frame:
Fault Status: 00110100
Fault Priority: 2
Fault Frequency: 2
Reset counter: 67
Mileage: 57755 km
Time Indication: 0
Date: 2015.02.15
Time: 00:03:41
01303 - Telephone Transceiver (R36)
004 - No Signal/Communication
Freeze Frame:
Fault Status: 01100100
Fault Priority: 2
Fault Frequency: 1
Reset counter: 27
Mileage: 57755 km
Time Indication: 0
Date: 2015.02.15
Time: 17:50:25