Door Elect Driver - 3AA 959 701 A

Coding for Door Elect Driver 3AA.959.701A on Passat B7

3AA 959 701 A :002 / :0533
Кодировка: 02  00  B7 
label: 3C0-959-70X-GEN4.clb
Ошибки: 3
Fault 66048: Motor for Front Window Regulator
: Missing Calibration / Basic Setting
Fault 65793: Supply voltage
: Voltage too Low
Byte 0 [02] / Binary: 00000010
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 1 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 2 [B7] / Binary: 10110111
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Address 42: Door Elect, Driver (J386)       Labels:| 3C0-959-70X-GEN4.clb
   Part No SW: 3AA 959 701 A    HW: 3C0 959 793 C
   Component: TUER-SG FT    002 0533  
   Revision: 12110009    Serial number: 0006770439
   Coding: 0200B7
   Shop #: WSC 05311 115 00000
   ASAM Dataset: EV_TSGFPQ35BRFVW46X A04001
   ROD: EV_TSGFPQ35BRFVW46X_VW32.rod
   VCID: 356194D394417F21A2-8060
 
   Slave Driver: 
   Subsystem 1 - Part No SW: 3AA 959 703 A    HW: 3AA 959 795   Labels: 1K0-959-70X-GEN4.CLB
   Component: J388__TSG-HL  004 0503 
   Serial number: 00000003410154      
   Coding: 010090
 
3 Faults Found:
65537 - Function Restricted due to Missing Message(s) 
          U1111 00 [008] - -
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 40
                    Mileage: 453921 km
                    Date: 2022.07.12
                    Time: 00:00:02
 
66048 - Motor for Front Window Regulator 
          B11EC 54 [009] - Missing Calibration / Basic Setting
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 7
                    Fault Frequency: 1
                    Reset counter: 0
                    Mileage: 453921 km
                    Date: 2022.07.11
                    Time: 07:43:03
 
65793 - Supply voltage 
          U1011 00 [009] - Voltage too Low
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 40