AccStart Auth - 3Q0 959 435 E

Coding for AccStart Auth 3Q0.959.435E on Passat B8

3Q0 959 435 E :036 / :0811
Кодировка: 0F  20  00  07  0F 
label: 5Q0-959-435.clb
Byte 0 [0F] / Binary: 00001111
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 1 [20] / Binary: 00100000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 2 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 3 [07] / Binary: 00000111
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 4 [0F] / Binary: 00001111
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Address 05: Acc/Start Auth. (J518)       Labels:| 5Q0-959-435.clb
   Part No SW: 3Q0 959 435 E    HW: 3Q0 959 435 E
   Component: VWKESSYMQB    036 0811  
   Revision: 00036000    Serial number: 0415656031
   Coding: 0F2000070F
   Shop #: WSC 05311 115 00310
   ASAM Dataset: EV_KessyHellaMQBAB 004039
   ROD: EV_KessyHellaMQBAB_VW48.rod
   VCID: 3C20CF4B66E29107D5F-8068
 
   Sensor Controlled Power Rear Lid: 
 
1 Fault Found:
65794 - Function Restricted due to Insufficient Voltage 
          U1400 00 [008] - -
          [Function restriction due to temp low voltage]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 69
                    Reset counter: 128
                    Mileage: 158686 km
                    Date: 2019.12.28
                    Time: 07:59:04
 
                    Terminal_15_Kessy_specified_value: On
                    Terminal_15_Kessy_actual_value: On
                    Terminal_15_central electric_actual_value: On
                    Terminal_15red_Kessy_specified_value: On
                    Terminal_15red_Kessy_actual_value: On
                    Terminal_S_Kessy_specified_value: On
                    Terminal_S_Kessy_actual_value: On
                    Terminal_S_central electric_actual_value: On
                    Terminal_50_Kessy_specified_value: OFF
                    Terminal_50_Kessy_actual_value: OFF
                    ZAT_pressed: OFF
                    Park selector lever position: Not engaged and not locked
                    Request active: Condition not met
                    Enabling Steering Column Lock: Condition not met
                    Enabling immobilizer: Condition met
                    No active error mode: Condition met
                    Key signature validity: Condition met
                    Control Module Voltage: 8.710 V
                    Driver information key position copy workshop: not active
                    Driver information: roll warning: not active
                    Driver information: emergency shutdown: not active
                    Internal_key_position: no_message
                    Driver information comfort switching: not active
                    Vehicle speed: 0.0 km/h
                    Engine speed: 121.0 /min
                    Status of vehicle locking: Vehicle unlocked at single door
                    Approach to the inside: not active
                    Actuation to the inside: not active
                    Approach to the outside: not active
                    Actuation to the outside: not active
                    Pulling actuation: outside door handle: not active
                    Coding information: coded
                    Approach to the inside: not active
                    Actuation to the inside: not active
                    Approach to the outside: not active
                    Actuation to the outside: not active
                    Pulling actuation: outside door handle: not active
                    Coding information: coded
                    Approach to the inside: not active
                    Actuation to the inside: not active
                    Approach to the outside: not active
                    Actuation to the outside: not active
                    Pulling actuation: outside door handle: not active
                    Coding information: coded
                    Approach to the inside: not active
                    Actuation to the inside: not active
                    Approach to the outside: not active
                    Actuation to the outside: not active
                    Pulling actuation: outside door handle: not active
                    Coding information: coded
                    Driver door: closed
                    Front Passenger Door: closed
                    Left rear door: closed
                    Right rear door: closed
                    Active_LF_scans: Init
                    ID sensor 1 authentication: status: No response
                    ID sensor 2 authentication: status: No response
                    ID sensor 3 authentication: status: No response
                    ID sensor 4 authentication: status: No response
                    SPN_Byte 0: 00
                    SPN_Byte 1: 00
                    SPN_Byte 2: 00