Auto Dist Reg - 2Q0 907 572 M

Coding for Auto Dist Reg 2Q0.907.572M on Tiguan

2Q0 907 572 M :H01 / :0233
Кодировка: 32  00  67  C3  58  FF  87  28  74  9C  81  45  30  40  87 
label: 2Q0-907-572.clb
Ошибки: 2
Fault 1086: Databus
: Missing Message
Fault 0836: Databus
: Received Error Message
Byte 0 [32] / Binary: 00110010
☐ bit 0
☑ bit 1
☐ bit 2
☐ bit 3
☑ bit 4
☑ bit 5
☐ bit 6
☐ bit 7
Byte 1 [00] / Binary: 00000000
☐ bit 0
☐ bit 1
☐ bit 2
☐ bit 3
☐ bit 4
☐ bit 5
☐ bit 6
☐ bit 7
Byte 2 [67] / Binary: 01100111
☑ bit 0
☑ bit 1
☑ bit 2
☐ bit 3
☐ bit 4
☑ bit 5
☑ bit 6
☐ bit 7
Byte 3 [C3] / Binary: 11000011
☑ bit 0
☑ bit 1
☐ bit 2
☐ bit 3
☐ bit 4
☐ bit 5
☑ bit 6
☑ bit 7
Byte 4 [58] / Binary: 01011000
☐ bit 0
☐ bit 1
☐ bit 2
☑ bit 3
☑ bit 4
☐ bit 5
☑ bit 6
☐ bit 7
Byte 5 [FF] / Binary: 11111111
☑ bit 0
☑ bit 1
☑ bit 2
☑ bit 3
☑ bit 4
☑ bit 5
☑ bit 6
☑ bit 7
Byte 6 [87] / Binary: 10000111
☑ bit 0
☑ bit 1
☑ bit 2
☐ bit 3
☐ bit 4
☐ bit 5
☐ bit 6
☑ bit 7
Byte 7 [28] / Binary: 00101000
☐ bit 0
☐ bit 1
☐ bit 2
☑ bit 3
☐ bit 4
☑ bit 5
☐ bit 6
☐ bit 7
Byte 8 [74] / Binary: 01110100
☐ bit 0
☐ bit 1
☑ bit 2
☐ bit 3
☑ bit 4
☑ bit 5
☑ bit 6
☐ bit 7
Byte 9 [9C] / Binary: 10011100
☐ bit 0
☐ bit 1
☑ bit 2
☑ bit 3
☑ bit 4
☐ bit 5
☐ bit 6
☑ bit 7
Byte 10 [81] / Binary: 10000001
☑ bit 0
☐ bit 1
☐ bit 2
☐ bit 3
☐ bit 4
☐ bit 5
☐ bit 6
☑ bit 7
Byte 11 [45] / Binary: 01000101
☑ bit 0
☐ bit 1
☑ bit 2
☐ bit 3
☐ bit 4
☐ bit 5
☑ bit 6
☐ bit 7
Byte 12 [30] / Binary: 00110000
☐ bit 0
☐ bit 1
☐ bit 2
☐ bit 3
☑ bit 4
☑ bit 5
☐ bit 6
☐ bit 7
Byte 13 [40] / Binary: 01000000
☐ bit 0
☐ bit 1
☐ bit 2
☐ bit 3
☐ bit 4
☐ bit 5
☑ bit 6
☐ bit 7
Byte 14 [87] / Binary: 10000111
☑ bit 0
☑ bit 1
☑ bit 2
☐ bit 3
☐ bit 4
☐ bit 5
☐ bit 6
☑ bit 7
Address 13: Auto Dist. Reg (J428)       Labels:| 2Q0-907-572.clb
   Part No SW: 2Q0 907 572 M    HW: 2Q0 907 572 B
   Component: ACCCONTIMQB   H01 0233  
   Coding: 320067C358FF8728749C8145304087
   Shop #: WSC 131071 1023 2097151
   ASAM Dataset: EV_ACCMRRCONTIVW376 002012
   ROD: EV_ACCMRRCONTIVW376_002.rod
   VCID: 3E2539D360FF8BC7FBB-806A

2 Faults Found:
1086 - Databus 
          U1121 00 [008] - Missing Message
          [FAULT_TIMEOUT_TSG_FT_02]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 4
                    Fault Frequency: 1
                    Reset counter: 155
                    Mileage: 52512 km
                    Date: 2019.09.14
                    Time: 11:50:32

                    Voltage terminal 15: 12.0 V
                    Control Module temperature: 44 ∞C
                    Velocity_vehicle_reference: 0.00 m/s
                    Longitudinal_acceleration_vehicle_reference: 0.28 m/s≤
                    Status_ACC_System: ACC_StandBy

0836 - Databus 
          U1123 00 [008] - Received Error Message
          [FAULT_PREDICTIVE_ROUTEDATA_SIGNALERROR_RECEIVED]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 17
                    Reset counter: 170
                    Mileage: 52542 km
                    Date: 2019.09.15
                    Time: 10:32:09

                    Voltage terminal 15: 13.9 V
                    Control Module temperature: 36 ∞C
                    Velocity_vehicle_reference: 0.00 m/s
                    Longitudinal_acceleration_vehicle_reference: 0.03 m/s≤
                    Status_ACC_System: ACC_StandBy