Byte 0 [02]
/ Binary: 00000010
|
bit 0-3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 1 [02]
/ Binary: 00000010
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 2 [01]
/ Binary: 00000001
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 3 [14]
/ Binary: 00010100
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 4 [10]
/ Binary: 00010000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6-7 |
|
# |
Byte 5 [21]
/ Binary: 00100001
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 6 [00]
/ Binary: 00000000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 7 [00]
/ Binary: 00000000
|
bit 0 |
Climate Modes active/displayed
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 8 [00]
/ Binary: 00000000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 9 [05]
/ Binary: 00000101
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 10 [00]
/ Binary: 00000000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 11 [40]
/ Binary: 01000000
|
bit 0 |
|
bit 1 |
|
bit 2-3 |
|
bit 4 |
Frequency Shift for Blower Control Module active
|
bit 5 |
|
bit 6 |
Blower Status Display in Auto-Mode active
|
bit 7 |
|
# |
Byte 12 [00]
/ Binary: 00000000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 13 [11]
/ Binary: 00010001
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 14 [18]
/ Binary: 00011000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 15 [02]
/ Binary: 00000010
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
Address 08: Auto HVAC (J255) Labels:| 5G0-907-044.clb
Part No SW: 5GM 907 044 A HW: 5GM 907 044 A
Component: Climatronic H03 1001
Revision: 00001K01
Coding: 02020114102100000005004000111802
Shop #: WSC 01383 790 50316
ASAM Dataset: EV_ACClimaBHBVW37X 003018
ROD: EV_ACClimaBHBVW37X_003_VW37.rod
VCID: 428A7294D58FD056DC-8016
Fresh Air Blower Front:
Refrigerant Pressure And Temperature Sender:
Air quality sensor:
1 Fault Found:
1048835 - Functionality limited due to Engine Control Module
P1719 00 [008] - -
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 9
Reset counter: 66
Mileage: 16221 km
Date: 2019.01.06
Time: 11:18:30
Voltage terminal 30: 13.6 V
Auxiliary heater: in stages-Enabling for auxiliary heater operation: Enabling stage 3
Auxiliary heater: in stages-Act.val.: 3
Auxiliary heater: in stages-Specified value: 3
Auxiliary heater: in stages-Specified value for control: 3