Byte 0 [5D]
/ Binary: 01011101
|
bit 0 |
Transverse Steering Column installed
|
bit 1 |
|
bit 2 |
|
bit 3 |
Automatic Transmission installed
|
bit 4 |
|
bit 5 |
|
bit 6 |
S-Contact Shut-Off after Timeout enabled
|
bit 7 |
|
# |
Byte 1 [00]
/ Binary: 00000000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 2 [00]
/ Binary: 00000000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 3 [00]
/ Binary: 00000000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 4 [00]
/ Binary: 00000000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 5 [00]
/ Binary: 00000000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 6 [00]
/ Binary: 00000000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 7 [00]
/ Binary: 00000000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
Address 2B: Steer. Col. Lock (J764) Labels:* 5Q0-905-861.clb
Part No SW: 5Q0 905 861 A HW: 5Q0 905 861 A
Component: ELV-MQBA H01 0120
Revision: 00000000 Serial number: 15000006284003
Coding: 5D00000000000000
Shop #: WSC 06385 790 00016
ASAM Dataset: EV_ELVMarquMQB 004111
ROD: EV_ELVMarquMQB.rod
VCID: 3449E55C9FA747EF73-8060
1 Fault Found:
13637378 - Databus
U1123 00 [008] - Received Error Message
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 98
Reset counter: 204
Mileage: 35121 km
Date: 2019.11.02
Time: 09:19:16
ELV State: 02
Information Clamps: 00 00
CoCo State: 20 01
WFS State: 00 06
Vehicle speed: 0.00 km/h
Voltage: 6C
AD-Value H-bridge: 36
Clamp15 flip flop: SSTx: button contacts: 09
CAN signals: 00