Byte 0 [12]
/ Binary: 00010010
|
bit 0-3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 1 [02]
/ Binary: 00000010
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 2 [01]
/ Binary: 00000001
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 3 [24]
/ Binary: 00100100
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 4 [20]
/ Binary: 00100000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6-7 |
|
# |
Byte 5 [24]
/ Binary: 00100100
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 6 [10]
/ Binary: 00010000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 7 [01]
/ Binary: 00000001
|
bit 0 |
Climate Modes active/displayed
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 8 [11]
/ Binary: 00010001
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 9 [15]
/ Binary: 00010101
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 10 [50]
/ Binary: 01010000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 11 [0E]
/ Binary: 00001110
|
bit 0 |
|
bit 1 |
|
bit 2-3 |
|
bit 4 |
Frequency Shift for Blower Control Module active
|
bit 5 |
|
bit 6 |
Blower Status Display in Auto-Mode active
|
bit 7 |
|
# |
Byte 12 [00]
/ Binary: 00000000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 13 [10]
/ Binary: 00010000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 14 [18]
/ Binary: 00011000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-7 |
|
# |
Byte 15 [2A]
/ Binary: 00101010
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
Address 08: Auto HVAC (J255) Labels: 5G0-907-044.clb
Part No SW: 5G0 907 044 BP HW: 5G0 907 044 BP
Component: Climatronic H04 1601
Revision: 00001K10
Coding: 12020124202410011115500E0010182A
Shop #: WSC 00015 115 08193
ASAM Dataset: EV_ACClimaBHBVW37X 006142
ROD: EV_ACClimaBHBVW37X_004_VW48.rod
VCID: 76B6EC59584D8647053-8022
Fresh Air Blower Front:
Refrigerant Pressure And Temperature Sender:
Air quality sensor:
Relative humidity sensor in fresh air intake duct:
1 Fault Found:
1048835 - Functionality limited due to Engine Control Module
P1719 00 [008] - -
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 2
Reset counter: 128
Mileage: 3430 km
Date: 2017.01.01
Time: 01:22:48
Voltage terminal 30: 14.4 V
Auxiliary heater: in stages-Enabling for auxiliary heater operation: Enabling stage 3
Auxiliary heater: in stages-Act.value: 2
Auxiliary heater: in stages-Specified value: 3
Auxiliary heater: in stages-Specified value for control: 3