Information Electr - 5C0 035 680 B

Coding for Information Electr 5C0.035.680B on Golf Plus

5C0 035 680 B :H22 / :0245
Coding: 02  73  00  01  FF  00  00  00  11  11  00  01  00  08  08  00  1F  01  00  D4  00  20  01  00  4F 
label: 5G0-035-MIB-STD2.clb
Faults: 2
Fault 1562: Microphone 1
: Short to Ground
Byte 0 [02] / Binary: 00000010
bit 0-23
Byte 1 [73] / Binary: 01110011
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 2 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 3 [01] / Binary: 00000001
bit 0-7
Byte 4 [FF] / Binary: 11111111
bit 0-31
Byte 5 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 6 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 7 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 8 [11] / Binary: 00010001
bit 0 Microphone 1 connected [PR-UE4/UI2/UI4]
bit 1
bit 2
bit 3
bit 4 AUX-IN Connection active [PR-UE4/UI2/UI4]
bit 5
bit 6 VDA Low Frequency Input active
bit 7
Byte 9 [11] / Binary: 00010001
bit 0
bit 1
bit 2
bit 3
bit 4-7
Byte 10 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4-7
Byte 11 [01] / Binary: 00000001
bit 0-7
Byte 12 [00] / Binary: 00000000
bit 0-3
bit 4
bit 5
bit 6
bit 7
Byte 13 [08] / Binary: 00001000
bit 0
bit 1
bit 2
bit 3 Radio Text Plus (RT+) active [STANDARD]
bit 4 PI Ignore active
bit 5
bit 6
bit 7 DAB Alarm Announcement active [PR-QV3]
Byte 14 [08] / Binary: 00001000
bit 0
bit 1 AM-Band Hide Switch active
bit 2
bit 3 Multiple Entry Switch active
bit 4
bit 5
bit 6
bit 7
Byte 15 [00] / Binary: 00000000
bit 0 Telephone Baseplate installed [PR-9IF]
bit 1 Telephone Antenna Baseplate installed [PR-9IF]
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 16 [1F] / Binary: 00011111
bit 0
bit 1
bit 2
bit 3
bit 4-5
bit 6
bit 7
Byte 17 [01] / Binary: 00000001
bit 0-7
Byte 18 [00] / Binary: 00000000
bit 0-7
Byte 19 [D4] / Binary: 11010100
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6-7
Byte 20 [00] / Binary: 00000000
bit 0 Display 1 installed/connected
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 21 [20] / Binary: 00100000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5 Messaging via MAP active
bit 6
bit 7
Byte 22 [01] / Binary: 00000001
bit 0 Instrument Cluster Graphics [STANDARD]
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 23 [00] / Binary: 00000000
bit 0 Speller Function active
bit 1
bit 2 Legal Disclaimer active
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 24 [4F] / Binary: 01001111
bit 0 Emergency Call active/installed
bit 1 Speech Dialog System (SDS) active/installed [PR-QH1/QH8]
bit 2 Navigation Function active/installed [PR-7UF/7UP/7UQ]
bit 3 WIFI Function active/installed [PR-9IE/9IF]
bit 4
bit 5
bit 6 Traffic Sign Display (VZA) active
bit 7 Predictive Route Data (PSD) active
Address 5F: Information Electr. (J794)       Labels:| 5G0-035-MIB-STD2.clb
   Part No SW: 5C0 035 680 B    HW: 5C0 035 680 B
   Component: MU-S-N-ER     H22 0245  
   Serial number: --------------
   Coding: 02730001FF00000011110001000808001F0100D4002001004F
   Shop #: WSC 00015 115 00001
   ASAM Dataset: EV_MUStd4CTSAT 001022
   ROD: EV_MUStd4CTSAT_VW26.rod
   VCID: 204F8E8A3B2F5146AA-8074
 
   Data medium: 
   Subsystem 1 - Part No SW: 3G0 919 866 BC    HW: -----------
   Component: ECE1 2017/18  --- 0820 
   Serial number: --------------------
 
2 Faults Found:
1562 - Microphone 1 
          B129B 11 [009] - Short to Ground
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 4
                    Fault Frequency: 1
                    Reset counter: 5
                    Mileage: 71499 km
                    Date: 2017.10.22
                    Time: 09:57:13
 
                    Voltage terminal 30: 14.1 V
 
7201 - Function Restricted due to Missing Message(s) 
          U1111 00 [009] - -
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 5
                    Mileage: 71499 km
                    Date: 2017.10.22
                    Time: 09:57:15
 
                    Voltage terminal 30: 14.0 V
                    BAP-BAP_Function_ID: 02
  
End-------------------------(Elapsed Time: 02:43)--------------------------