Auto HVAC - 5K0 907 044 ES
Coding for Auto HVAC 5K0907044ES on Golf
5K0 907 044 ES
:H18 /
:1112
Coding: 00 04 00 48 03
Coding: 00 04 00 48 03
label:
5K0-907-044.clb
- Show complete log #316 for Golf 2008 (16 control modules, scanned at 11.12.2019)
- Show more logs for Volkswagen Golf 2008
- Show more items 5K0 907 044 ES
Faults: 6
Fault 9484401: Motor for Indirect Ventilation Flap
: Actuator stuck
: Actuator stuck
Fault 9484402: Motor for Indirect Ventilation Flap
: Missing Calibration / Basic Setting
: Missing Calibration / Basic Setting
Fault 9481988: Air Quality Sensor
: Internal System Fault
: Internal System Fault
Fault 9479189: Signal Line for Air Quality Sensor
: Open or Short to Plus
: Open or Short to Plus
| # |
Byte 0 [00]
/ Binary: 00000000 |
|---|---|
| bit 0-5 | |
| bit 6 | |
| bit 7 |
| # |
Byte 1 [04]
/ Binary: 00000100 |
|---|---|
| bit 0-2 | |
| bit 3 | Extended Display Temperature Range active |
| bit 4 | Function Light Dimming via Light Sensor active |
| bit 5 | |
| bit 6 | |
| bit 7 |
| # |
Byte 2 [00]
/ Binary: 00000000 |
|---|---|
| bit 0 | |
| bit 1 | |
| bit 2 | |
| bit 3-5 | |
| bit 6 | |
| bit 7 |
| # |
Byte 3 [48]
/ Binary: 01001000 |
|---|---|
| bit 0 | |
| bit 1 | |
| bit 2 | |
| bit 3 | |
| bit 4-6 | |
| bit 7 | Blower/Display Logic for absolute Blower Voltage without Blower Stage Display |
| # |
Byte 4 [03]
/ Binary: 00000011 |
|---|---|
| bit 0 | |
| bit 1-3 | |
| bit 4 | |
| bit 5 | |
| bit 6 | Compressor Shutoff via Humidity Sensor active |
| bit 7 |
Address 08: Auto HVAC (J255) Labels:| 5K0-907-044.clb
Part No SW: 5K0 907 044 ES HW: 5K0 907 044 ES
Component: Climatronic H18 1112
Revision: 00001004
Coding: 0004004803
Shop #: WSC 00015 115 00000
ASAM Dataset: EV_Climatronic A01010
ROD: EV_ClimaAutoBasis_VW36.rod
VCID: 0021798C9B9F2B4FA7-8054
6 Faults Found:
9484401 - Motor for Indirect Ventilation Flap
B10B8 71 [008] - Actuator stuck
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 4
Reset counter: 39
Mileage: 189039 km
Date: 2000.00.00
Time: 14:54:14
9484402 - Motor for Indirect Ventilation Flap
B10B8 54 [009] - Missing Calibration / Basic Setting
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 253
Mileage: 189039 km
Date: 2000.00.00
Time: 14:53:04
13701376 - Function Restricted due to Missing Message(s)
U1111 00 [009] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 3
Reset counter: 254
Mileage: 189039 km
Date: 2000.00.00
Time: 14:53:05
13701456 - Function Restricted due to Missing Message(s)
U1111 00 [009] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 3
Reset counter: 254
Mileage: 189039 km
Date: 2000.00.00
Time: 14:53:05
9481988 - Air Quality Sensor
B10AF 04 [008] - Internal System Fault
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 3
Fault Frequency: 254
Reset counter: 38
Mileage: 442853 km
Date: 2083.14.30
Time: 10:43:09
9479189 - Signal Line for Air Quality Sensor
B10A4 15 [009] - Open or Short to Plus
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 3
Fault Frequency: 4
Reset counter: 254
Mileage: 189039 km
Date: 2000.00.00
Time: 14:53:52