Information Electr - 5NA 035 045

Coding for Information Electr 5NA.035.045 on Golf

5NA 035 045 :H51 / :0981
Coding: 02  73  00  0C  00  00  00  00  51  11  00  02  00  18  28  00  1F  02  07  F4  01  20  00  00  DF 
label: None
Byte 0 [02] / Binary: 00000010
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 1 [73] / Binary: 01110011
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 2 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 3 [0C] / Binary: 00001100
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 4 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 5 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 6 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 7 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 8 [51] / Binary: 01010001
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 9 [11] / Binary: 00010001
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 10 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 11 [02] / Binary: 00000010
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 12 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 13 [18] / Binary: 00011000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 14 [28] / Binary: 00101000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 15 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 16 [1F] / Binary: 00011111
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 17 [02] / Binary: 00000010
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 18 [07] / Binary: 00000111
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 19 [F4] / Binary: 11110100
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 20 [01] / Binary: 00000001
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 21 [20] / Binary: 00100000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 22 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 23 [00] / Binary: 00000000
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Byte 24 [DF] / Binary: 11011111
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Address 5F: Information Electr. (J794)       Labels:* None
   Part No SW: 5NA 035 045     HW: 5NA 035 045 
   Component: MU-H-N-RW     H51 0981  
   Serial number: A849L0HB001908
   Coding: 0273000C0000000051110002001828001F0207F401200000DF
   Shop #: WSC 35332 001 104857
   ASAM Dataset: EV_MUHig4CGen2HBAS 001001
   ROD: EV_MUHig4CGen2HBAS_VW37.rod
   VCID: 75A20F9AD4480FEC04-8020

   Operating And Display Unit 1: 
   Subsystem 1 - Part No SW: 5G6 919 606     HW: 5G6 919 606 
   Component: ABT_High-2  H35 9074 
   Serial number: VWZ6ZFS2960131      

   Data medium: 
   Subsystem 2 - Part No SW: V03 959 801 EC    HW: -----------
   Component: ROW 2017  --- 0062 
   Serial number: --------------------

   Compact Disc Database: 
   Subsystem 3 - Part No SW: V03 959 800 EG    HW: -----------
   Component: Gracenote2  --- 4011 
   Serial number: --------------------

9 Faults Found:
1586 - invalid data record 
          B2005 00 [009] -  - 
          [Control module (data record download) - invalid data record for speed shutoff thresholds]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 44
                    Mileage: 14793 km
                    Date: 2018.09.30
                    Time: 12:51:01

                    Voltage terminal 30: 13.8 V

1587 - invalid data record 
          B2005 00 [009] -  - 
          [Control module (data record download) - invalid data record for language]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 44
                    Mileage: 14793 km
                    Date: 2018.09.30
                    Time: 12:51:01

                    Voltage terminal 30: 13.8 V

1588 - invalid data record 
          B2005 00 [009] -  - 
          [Control module (data record download) - invalid data record for visible MMI system languages]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 44
                    Mileage: 14793 km
                    Date: 2018.09.30
                    Time: 12:51:01

                    Voltage terminal 30: 13.8 V

1589 - invalid data record 
          B2005 00 [009] -  - 
          [Control module (data record download) - invalid data record for power management timer]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 44
                    Mileage: 14793 km
                    Date: 2018.09.30
                    Time: 12:51:01

                    Voltage terminal 30: 13.8 V

1595 - invalid data record 
          B2005 00 [009] -  - 
          [Control module (data record download) - invalid data record for audio management HMI constants]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 44
                    Mileage: 14793 km
                    Date: 2018.09.30
                    Time: 12:51:01

                    Voltage terminal 30: 13.8 V

1652 - invalid data record 
          B2005 00 [009] -  - 
          [Control module (data record download) - invalid data record for eco HMI]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 44
                    Mileage: 14793 km
                    Date: 2018.09.30
                    Time: 12:51:01

                    Voltage terminal 30: 13.8 V

1597 - Data Set Implausible 
          B2012 00 [009] -  - 
          [Control module (data record download) - implausible data record for language]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 44
                    Mileage: 14793 km
                    Date: 2018.09.30
                    Time: 12:51:01

                    Voltage terminal 30: 13.8 V

1598 - Data Set Implausible 
          B2012 00 [009] -  - 
          [Control module (data record download) - implausible data record for visible MMI system languages]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 44
                    Mileage: 14793 km
                    Date: 2018.09.30
                    Time: 12:51:01

                    Voltage terminal 30: 13.8 V

1555 - Check Software Version Management 
          B201A 00 [009] -  - 
          [Check software version management]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 44
                    Mileage: 14793 km
                    Date: 2018.09.30
                    Time: 12:51:06

                    Voltage terminal 30: 13.8 V
                    Status_Software_Version_Management-module_name: MMIBLite/MIBLite