Door Elect Pass - 1K0 959 702 P
Coding for Door Elect Pass 1K0959702P on Golf
1K0 959 702 P
: /
:1134
Coding: 00 00 69 2
Coding: 00 00 69 2
label:
1K0-959-702-MIN3.lbl
Faults: 2
Fault 01812: Supply Voltage for Door Controller; Pass. Side (J387)
: Lower Limit Exceeded
: Lower Limit Exceeded
Fault 00933: Electric Window Motor; Passenger Side (V148)
: No or Incorrect Basic Setting / Adaptation
: No or Incorrect Basic Setting / Adaptation
# |
Byte 0 [00]
/ Binary: 00000000 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
# |
Byte 1 [00]
/ Binary: 00000000 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
# |
Byte 2 [69]
/ Binary: 01101001 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
# |
Byte 3 [02]
/ Binary: 00000010 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
Address 52: Door Elect, Pass. Labels: 1K0-959-702-MIN3.lbl Part No SW: 1K0 959 702 P HW: 1K0 959 792 L Component: J387 TUER-SG BT 1134 Revision: 32008001 Serial number: 00000103278711 Coding: 0000692 Shop #: WSC 00066 000 00000 VCID: 3C59CD7C7FF78FDCA8-8068 2 Faults Found: 01812 - Supply Voltage for Door Controller; Pass. Side (J387) 002 - Lower Limit Exceeded - Intermittent 00933 - Electric Window Motor; Passenger Side (V148) 005 - No or Incorrect Basic Setting / Adaptation - Intermittent