Door Elect Pass - 3AA 998 702
Coding for Door Elect Pass 3AA998702 on Passat
3AA 998 702
:002 /
:0601
Coding: 80 20 90
Coding: 80 20 90
label:
None
Faults: 5
Fault 65538: Local Data Bus
: No Communication
: No Communication
Fault 66048: Motor for Front Window Regulator
: Missing Calibration / Basic Setting
: Missing Calibration / Basic Setting
Fault 67074: Motors for Central Locking
: Electrical Failure
: Electrical Failure
Fault 67330: Switch for Central Locking
: Signal Implausible
: Signal Implausible
# |
Byte 0 [80]
/ Binary: 10000000 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
# |
Byte 1 [20]
/ Binary: 00100000 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
# |
Byte 2 [90]
/ Binary: 10010000 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
Address 52: Door Elect, Pass. (J387) Labels:* None Part No SW: 3AA 998 702 HW: 3C0 959 792 J Component: TUER-SG BT 002 0601 Revision: 14100010 Serial number: 0010099726 Coding: 802090 Shop #: WSC 00000 000 00000 ASAM Dataset: EV_TSGBPQ35BRFVW46X A04004 ROD: EV_TSGBPQ35BRFVW46X_VW32.rod VCID: 78FF5DE7C3D342497A-802C 5 Faults Found: 65538 - Local Data Bus U10BA 00 [009] - No Communication [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 4 Fault Frequency: 1 Reset counter: 219 Mileage: 232182 km Date: 2023.05.04 Time: 21:44:32 65539 - Control module not coded U1013 00 [009] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 2 Fault Frequency: 1 Reset counter: 219 Mileage: 232182 km Date: 2023.05.04 Time: 21:44:32 66048 - Motor for Front Window Regulator B11EC 54 [008] - Missing Calibration / Basic Setting Intermittent - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 7 Fault Frequency: 1 Reset counter: 6 67074 - Motors for Central Locking B122B 01 [009] - Electrical Failure Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 2 Fault Frequency: 1 Reset counter: 219 Mileage: 232182 km Date: 2023.05.04 Time: 22:35:57 67330 - Switch for Central Locking B122D 29 [009] - Signal Implausible Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 2 Fault Frequency: 12 Reset counter: 222 Mileage: 232182 km Date: 2023.05.04 Time: 22:36:02