Auto HVAC - 5K0 907 044 F
Coding for Auto HVAC 5K0.907.044F on Sharan
5K0 907 044 F
:H11 /
:0106
Coding: 00 00 00 00 09
Coding: 00 00 00 00 09
label:
5K0-907-044.clb
- Complete log #472 for Sharan 2011 (15 control modules, scanned at 03.11.2023)
- Logs for Volkswagen Sharan 2011
- More items 5K0.907.044F
Faults: 3
Fault 9481748: High Pressure Sensor
: Open or Short to Ground
: Open or Short to Ground
| Byte 0
[00]
/ Binary: 00000000 |
|
|---|---|
| ☐ bit 0-5 | |
| ☐ bit 6 | |
| ☐ bit 7 | |
| Byte 1
[00]
/ Binary: 00000000 |
|
|---|---|
| ☐ bit 0-2 | |
| ☐ bit 3 | Extended Display Temperature Range active |
| ☐ bit 4 | Function Light Dimming via Light Sensor active |
| ☐ bit 5 | Front Sunlight Photo Sensor with Light Recognition (PR-8N8+9AK) |
| ☐ bit 6 | |
| ☐ bit 7 | |
| Byte 2
[00]
/ Binary: 00000000 |
|
|---|---|
| ☐ bit 0 | |
| ☐ bit 1 | |
| ☐ bit 2 | |
| ☐ bit 3-5 | |
| ☐ bit 6 | |
| ☐ bit 7 | |
| Byte 3
[00]
/ Binary: 00000000 |
|
|---|---|
| ☐ bit 0 | |
| ☐ bit 1 | |
| ☐ bit 2 | |
| ☐ bit 3 | |
| ☐ bit 4-6 | |
| ☐ bit 7 | Blower/Display Logic for absolute Blower Voltage without Blower Stage Display |
| Byte 4
[09]
/ Binary: 00001001 |
|
|---|---|
| ☑ bit 0 | |
| ☐ bit 1 | |
| ☐ bit 2 | |
| ☑ bit 3 | |
| ☐ bit 4-5 | |
| ☐ bit 6 | Compressor Shutoff via Humidity Sensor active |
| ☐ bit 7 | Refrigerant: R1234YF (instead of R134a) |
Address 08: Auto HVAC (J255) Labels:| 5K0-907-044.clb
Part No SW: 5K0 907 044 F HW: 5K0 907 044 F
Component: Clima-Sharan H11 0106
Revision: 00002001
Coding: 0000000009
Shop #: WSC 00020 999 00000
ASAM Dataset: EV_ClimatronicSharan A01005
ROD: EV_ClimaAutoSharaBasis.rod
VCID: 2E05097DE092D97A8DF-807A
3 Faults Found:
13701376 - Function Restricted due to Missing Message(s)
U1111 00 [00001001] - -
[Motorsteuergerät - kein Signal/Kommunikation]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 8
Reset counter: 253
Mileage: 189427 km
Date: 2023.11.03
Time: 20:22:40
13701392 - Function Restricted due to Missing Message(s)
U1111 00 [00001001] - -
[Bremsensteuergerät - kein Signal/Kommunikation]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 8
Reset counter: 253
Mileage: 189427 km
Date: 2023.11.03
Time: 20:22:40
9481748 - High Pressure Sensor
B10AE 14 [00001001] - Open or Short to Ground
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 2
Fault Frequency: 2
Reset counter: 253
Mileage: 189427 km
Date: 2023.11.03
Time: 20:22:40