Byte 0
[13]
/ Binary: 00010011
|
|
☑
bit 0-3
|
|
|
☑
bit 4
|
|
|
☐
bit 5
|
|
|
☐
bit 6
|
|
|
☐
bit 7
|
|
Byte 1
[02]
/ Binary: 00000010
|
|
☐
bit 0
|
|
|
☑
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3
|
|
|
☐
bit 4-7
|
|
Byte 2
[00]
/ Binary: 00000000
|
|
☐
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3
|
|
|
☐
bit 4-7
|
|
Byte 3
[04]
/ Binary: 00000100
|
|
☐
bit 0
|
|
|
☐
bit 1
|
|
|
☑
bit 2
|
|
|
☐
bit 3
|
|
|
☐
bit 4-7
|
|
Byte 4
[60]
/ Binary: 01100000
|
|
☐
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3
|
|
|
☐
bit 4
|
|
|
☑
bit 5
|
|
|
☑
bit 6-7
|
|
Byte 5
[00]
/ Binary: 00000000
|
|
☐
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3
|
|
|
☐
bit 4-7
|
|
Byte 6
[00]
/ Binary: 00000000
|
|
☐
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3
|
|
|
☐
bit 4-7
|
|
Byte 7
[11]
/ Binary: 00010001
|
|
☑
bit 0
|
Climate Modes active/displayed
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3
|
|
|
☑
bit 4
|
|
|
☐
bit 5
|
|
|
☐
bit 6
|
|
|
☐
bit 7
|
|
Byte 8
[10]
/ Binary: 00010000
|
|
☐
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3
|
|
|
☑
bit 4-7
|
|
Byte 9
[15]
/ Binary: 00010101
|
|
☑
bit 0
|
|
|
☐
bit 1
|
|
|
☑
bit 2
|
|
|
☐
bit 3
|
|
|
☑
bit 4-5
|
|
|
☐
bit 6
|
|
|
☐
bit 7
|
|
Byte 10
[50]
/ Binary: 01010000
|
|
☐
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3
|
|
|
☑
bit 4
|
|
|
☐
bit 5
|
|
|
☑
bit 6
|
|
|
☐
bit 7
|
|
Byte 11
[41]
/ Binary: 01000001
|
|
☑
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2-3
|
|
|
☐
bit 4
|
Frequency Shift for Blower Control Module active
|
|
☐
bit 5
|
|
|
☑
bit 6
|
Blower Status Display in Auto-Mode active
|
|
☐
bit 7
|
|
Byte 12
[02]
/ Binary: 00000010
|
|
☐
bit 0
|
|
|
☑
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3
|
|
|
☐
bit 4-7
|
|
Byte 13
[11]
/ Binary: 00010001
|
|
☑
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3
|
|
|
☑
bit 4-5
|
|
|
☐
bit 6
|
|
|
☐
bit 7
|
|
Byte 14
[18]
/ Binary: 00011000
|
|
☐
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☑
bit 3
|
|
|
☑
bit 4-7
|
|
Byte 15
[09]
/ Binary: 00001001
|
|
☑
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☑
bit 3-4
|
|
|
☐
bit 5
|
Cabin Air Filtering active
|
|
☐
bit 6
|
|
|
☐
bit 7
|
|
Адрес 08: Электроника отопителя и климата (J255) Файл QML:| 5G0-907-044.clb
Номер детали ПО: 5G0 907 044 AA АО: 5G0 907 044 AA
Компонент: Climatronic H02 0705
Ревизия: 00001K06
Кодировка: 13020004600000111015504102111809
Мастерская #: WSC 01357 011 00200
Метка файла ASAM/ODX: EV_ACClimaBHBVW37X 003018
ODX: EV_ACClimaBHBVW37X_003_VW37.odx
Блок управления приточного вентилятора (пер.):
Датчик давления и температуры хладагента:
Датчик загрязнения воздуха:
1 неисправность:
328197 - Исп. электродвигатель правой заслонки регулирования температуры
B108D 54 [009] - Отсутствует калибровка/основная установка
Подтверждено - протестировано после удаления записей
Стоп-кадр:
Биты состояния: 00000001
Приоритетность: 2
Счётчик возникновения ошибки: 1
Индекс забывания: 189
Пробег: 164540 km
Дата: 2020.05.16
Время: 14:00:18
Напряжение клеммы 30: 11.1 V
Наружная температура: 16.0 °C
Температура в салоне: 25.2 °C
Правая заслонка регулирования температуры - факт. величина: 204
Правая заслонка регулирования температуры - факт. величина: 100.0 %
Правая заслонка регулирования температуры - ном. величина: 205