Auto HVAC - 5K0 907 044 EA
Coding for Auto HVAC 5K0.907.044EA on Golf Plus
5K0 907 044 EA
:H17 /
:1010
Coding: 00 00 00 00 02
Coding: 00 00 00 00 02
label:
5K0-907-044.clb
- Complete log #333 for Golf Plus 2011 (19 control modules, scanned at 04.08.2019)
- Logs for Volkswagen Golf Plus 2011
- More items 5K0.907.044EA
Faults: 2
Fault 9481748: High Pressure Sensor
: Open or Short to Ground
: Open or Short to Ground
| Byte 0
[00]
/ Binary: 00000000 |
|
|---|---|
| ☐ bit 0-5 | |
| ☐ bit 6 | |
| ☐ bit 7 | |
| Byte 1
[00]
/ Binary: 00000000 |
|
|---|---|
| ☐ bit 0-2 | |
| ☐ bit 3 | Extended Display Temperature Range active |
| ☐ bit 4 | Function Light Dimming via Light Sensor active |
| ☐ bit 5 | Front Sunlight Photo Sensor with Light Recognition (PR-8N8+9AK) |
| ☐ bit 6 | |
| ☐ bit 7 | |
| Byte 2
[00]
/ Binary: 00000000 |
|
|---|---|
| ☐ bit 0 | |
| ☐ bit 1 | |
| ☐ bit 2 | |
| ☐ bit 3-5 | |
| ☐ bit 6 | |
| ☐ bit 7 | |
| Byte 3
[00]
/ Binary: 00000000 |
|
|---|---|
| ☐ bit 0 | |
| ☐ bit 1 | |
| ☐ bit 2 | |
| ☐ bit 3 | |
| ☐ bit 4-6 | |
| ☐ bit 7 | Blower/Display Logic for absolute Blower Voltage without Blower Stage Display |
| Byte 4
[02]
/ Binary: 00000010 |
|
|---|---|
| ☐ bit 0 | |
| ☑ bit 1 | |
| ☐ bit 2 | |
| ☐ bit 3 | |
| ☐ bit 4-5 | |
| ☐ bit 6 | Compressor Shutoff via Humidity Sensor active |
| ☐ bit 7 | Refrigerant: R1234YF (instead of R134a) |
Address 08: Auto HVAC (J255) Labels:| 5K0-907-044.clb
Part No SW: 5K0 907 044 EA HW: 5K0 907 044 EA
Component: Climatronic H17 1010
Revision: 00003001
Coding: 0000000002
Shop #: WSC 01357 011 00200
ASAM Dataset: EV_Climatronic A01010
ROD: EV_ClimaAutoBasis_VW36.rod
VCID: 6EFD3734B10B2D3F7B-803A
2 Faults Found:
13701392 - Function Restricted due to Missing Message(s)
U1111 00 [008] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 1
Reset counter: 119
Mileage: 97708 km
Date: 2019.08.03
Time: 06:06:27
9481748 - High Pressure Sensor
B10AE 14 [008] - Open or Short to Ground
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 119
Mileage: 97708 km
Date: 2019.08.03
Time: 05:54:38