Byte 0
[00]
/ Binary: 00000000
|
|
☐
bit 0-5
|
|
|
☐
bit 6
|
|
|
☐
bit 7
|
|
Byte 1
[14]
/ Binary: 00010100
|
|
☐
bit 0-2
|
|
|
☐
bit 3
|
Extended Display Temperature Range active
|
|
☑
bit 4
|
Function Light Dimming via Light Sensor active
|
|
☐
bit 5
|
Front Sunlight Photo Sensor with Light Recognition (PR-8N8+9AK)
|
|
☐
bit 6
|
|
|
☐
bit 7
|
|
Byte 2
[00]
/ Binary: 00000000
|
|
☐
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3-5
|
|
|
☐
bit 6
|
|
|
☐
bit 7
|
|
Byte 3
[20]
/ Binary: 00100000
|
|
☐
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3
|
|
|
☐
bit 4-6
|
|
|
☐
bit 7
|
Blower/Display Logic for absolute Blower Voltage without Blower Stage Display
|
Byte 4
[03]
/ Binary: 00000011
|
|
☑
bit 0
|
|
|
☑
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3
|
|
|
☐
bit 4-5
|
|
|
☐
bit 6
|
Compressor Shutoff via Humidity Sensor active
|
|
☐
bit 7
|
Refrigerant: R1234YF (instead of R134a)
|
Address 08: Auto HVAC (J255) Labels:| 5K0-907-044.clb
Part No SW: 3AA 907 044 C HW: 3AA 907 044 C
Component: Climatronic H03 0404
Revision: 00001K01
Coding: 0014002003
Shop #: WSC 15602 938 99173
ASAM Dataset: EV_Climatronic A01010
ROD: EV_ClimaAutoBasis_VW46.rod
VCID: 303910DDCAA0AD5B573-8064
1 Fault Found:
9481988 - Air Quality Sensor
B10AF 04 [008] - Internal System Fault
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 3
Fault Frequency: 3
Reset counter: 138
Mileage: 85322 km
Date: 2023.01.08
Time: 03:08:07