SW Cluster Embedded -
Coding for SW Cluster Embedded on ID.3
:SWCL_Em /
:0297
Coding:
Coding:
label:
V04-007-003-SWC2.clb
- Show complete log #594 for ID.3 2022 (33 control modules, scanned at 04.08.2024)
- Show more logs for Volkswagen ID.3 2022
Faults: 3
Fault 8491267: Secure Onboard Communication
: Signature Generation Failed
: Signature Generation Failed
Fault 8491265: Secure Onboard Communication
: Time Server not Available
: Time Server not Available
Address C002: SW Cluster Embedded (SWC2) Labels: V04-007-003-SWC2.clb
Part No: V04 007 005 AD
Component: ICAS1 SWCL_Em 0297
Dataset Number: V03935362KU 0001
ASAM Dataset: EV_SWCLEmbed1ICAS1 005001
ROD: EV_SWCLEmbed1ICAS1.rod
VCID: 6B80CD27C30AF772EA1-803E SFD
3 Faults Found:
7467527 - Data Set Implausible
B2012 00 [00101111] - -
[Data_set_implausible_ECP]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Reset counter: 40
Date: 2000.00.00
Time: 00:00:00
8491267 - Secure Onboard Communication
U14FF 00 [01101101] - Signature Generation Failed
[SOK_signature_creation_failed]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 3
Fault Frequency: 3
Reset counter: 40
Mileage: 31365 km
Date: 2023.07.16
Time: 07:58:18
8491265 - Secure Onboard Communication
U14FD 00 [00100000] - Time Server not Available
[SOK_timeserver_not_available]
Intermittent - Not Confirmed - Tested Since Memory Clear