Byte 0
[00]
/ Binary: 00000000
|
|
☐
bit 0-5
|
|
|
☐
bit 6
|
|
|
☐
bit 7
|
|
Byte 1
[14]
/ Binary: 00010100
|
|
☐
bit 0-2
|
|
|
☐
bit 3
|
Extended Display Temperature Range active
|
|
☑
bit 4
|
Function Light Dimming via Light Sensor active
|
|
☐
bit 5
|
Front Sunlight Photo Sensor with Light Recognition (PR-8N8+9AK)
|
|
☐
bit 6
|
|
|
☐
bit 7
|
|
Byte 2
[00]
/ Binary: 00000000
|
|
☐
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3-5
|
|
|
☐
bit 6
|
|
|
☐
bit 7
|
|
Byte 3
[48]
/ Binary: 01001000
|
|
☐
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☑
bit 3
|
|
|
☐
bit 4-6
|
|
|
☐
bit 7
|
Blower/Display Logic for absolute Blower Voltage without Blower Stage Display
|
Byte 4
[03]
/ Binary: 00000011
|
|
☑
bit 0
|
|
|
☑
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3
|
|
|
☐
bit 4-5
|
|
|
☐
bit 6
|
Compressor Shutoff via Humidity Sensor active
|
|
☐
bit 7
|
Refrigerant: R1234YF (instead of R134a)
|
Address 08: Auto HVAC (J255) Labels:| 5K0-907-044.clb
Part No SW: 3AA 907 044 AG HW: 3AA 907 044 AG
Component: Climatronic H03 0303
Revision: 00001K02
Coding: 0014004803
Shop #: WSC 00015 115 00000
ASAM Dataset: EV_Climatronic A01010
ROD: EV_ClimaAutoBasis_VW36.rod (VIN: N/A)
VCID: 75E154D3D4C13F2162-8020
10 Faults Found:
13701376 - Function Restricted due to Missing Message(s)
U1111 00 [009] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 44
Reset counter: 0
Mileage: 453921 km
Date: 2022.06.05
Time: 00:17:40
13701888 - Function Restriction due to Faults in Other Modules
U1113 00 [008] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 1
Reset counter: 40
Mileage: 453920 km
Date: 2022.06.05
Time: 21:09:17
13701392 - Function Restricted due to Missing Message(s)
U1111 00 [008] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 4
Reset counter: 40
Mileage: 453921 km
Date: 2022.07.11
Time: 07:48:49
13701968 - Function Restriction due to Faults in Other Modules
U1113 00 [009] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 38
Reset counter: 0
Mileage: 453920 km
Date: 2022.06.05
Time: 21:09:17
13701504 - Function Restricted due to Missing Message(s)
U1111 00 [008] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 1
Reset counter: 40
Mileage: 453921 km
Date: 2022.07.12
Time: 00:00:03
13701536 - Function Restricted due to Missing Message(s)
U1111 00 [009] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 12
Reset counter: 0
Mileage: 453921 km
Date: 2022.07.12
Time: 00:00:03
9481746 - High Pressure Sensor
B10AE 12 [009] - Short to Plus
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 0
Mileage: 453921 km
Date: 2022.07.20
Time: 00:00:29
9481748 - High Pressure Sensor
B10AE 14 [008] - Open or Short to Ground
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 40
Mileage: 453920 km
Date: 2022.06.05
Time: 21:09:09
9480469 - Control Circuit for A/C Compressor
B10A9 15 [009] - Open or Short to Plus
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 0
Mileage: 453920 km
Date: 2022.06.05
Time: 21:09:10
13635840 - Supply voltage
U1011 00 [008] - Voltage too Low
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 1
Fault Frequency: 2
Reset counter: 40
Mileage: 453921 km
Date: 2022.07.11
Time: 02:11:44