Byte 0 [00]
/ Binary: 00000000
|
bit 0-5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 1 [00]
/ Binary: 00000000
|
bit 0-2 |
|
bit 3 |
Extended Display Temperature Range active
|
bit 4 |
Function Light Dimming via Light Sensor active
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 2 [00]
/ Binary: 00000000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3-5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 3 [01]
/ Binary: 00000001
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-6 |
|
bit 7 |
Blower/Display Logic for absolute Blower Voltage without Blower Stage Display
|
# |
Byte 4 [09]
/ Binary: 00001001
|
bit 0 |
|
bit 1-3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
Compressor Shutoff via Humidity Sensor active
|
bit 7 |
|
Address 08: Auto HVAC (J255) Labels: 5K0-907-044.clb
Part No SW: 5K0 907 044 F HW: 5K0 907 044 F
Component: Clima-Sharan H11 0103
Revision: 00002001
Coding: 0000000109
Shop #: WSC 00020 999 00000
ASAM Dataset: EV_ClimatronicHsaran A01005
ROD: N/A
VCID: 2E54D5FA718C05314B-807A
Subsystem 1 - Part No SW: 7N0 907 049 HW: 7N0 907 049
Component: KBT-H 001 0101
Serial number: 20100812000000002706
No ASAM data for: "EV_ClimatronicHsaran" (VW36 *)
1 Fault Found:
9601321 - ROD - Unknown Error Code
- 00 [008]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 8
Reset counter: 130
Mileage: 232204 km
Date: 2017.07.17
Time: 14:07:11