Batt. Chrg. - 1EA 915 684 EA
Coding for Batt. Chrg. 1EA915684EA on ID.3
1EA 915 684 EA
:H60 /
:1019
Coding: 10 80
Coding: 10 80
label:
1EA-915-684.clb
- Show complete log #594 for ID.3 2022 (33 control modules, scanned at 04.08.2024)
- Show more logs for Volkswagen ID.3 2022
- Show more items 1EA 915 684 EA
Faults: 5
Fault 3276840: Intelligent Charging
: Functional Restriction
: Functional Restriction
Fault 3280897: Charging Station
: Identification Failed
: Identification Failed
Fault 3280899: Charging Station
: Identification Failed
: Identification Failed
Fault 5242881: Communication Authentication
: Invalid Signal
: Invalid Signal
Fault 14750981: Charging Socket 1
: Unlock Prohibited
: Unlock Prohibited
# |
Byte 0 [10]
/ Binary: 00010000 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
# |
Byte 1 [80]
/ Binary: 10000000 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
Address C6: Batt. Chrg. (J1050) Labels:| 1EA-915-684.clb Part No SW: 1EA 915 684 EA HW: 1EA 915 684 BK Component: HV_CHARGER H60 1019 Serial number: 93286UGD0000I Coding: 1080 ASAM Dataset: EV_OCCXPhase1KLOMEB01B 002017 ROD: EV_OCCXPhase1KLOMEB01B.rod VCID: 7EA6F473A07872DA5DF-802A 5 Faults Found: 3276840 - Intelligent Charging U15A9 00 [01101000] - Functional Restriction [ETHTRCV_30_AR7000_E_ACCESS] Intermittent - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 2 Reset counter: 21 Mileage: 41972 km Date: 2024.01.28 Time: 22:05:42 DID 1DA0: AC main charge DID 1DAC: Charging Frequency: 1000 Hz Control voltage: 6056.0 mV Duty cycle: 16.1 % Activation charge cover lock charge socket A: not requested Lock for high-voltage charging connector: locked Status connect. recognition: detected Charge socket temperature sensor AC: 30.0 °C Temperature sensor 1: resistance value: 1095 Ohm DID 15E2: 14.0 °C DID 081C: 0 W DID 081D: 1 W DID 081E: 2108 W DID 0286: 13.3 V DID 497C: not active DID 537A: 14.3 V DID 1525: 3870 mV DID 4219: High voltage power off not recognized DID 5372: 13.0 °C No. of lockings: 3180 No. of connections: 171 Number of successful charging connector locks: 963 Wake-up counter: contact (proximity): 0 Wake-up counter: Control Pilot: 1 Charging standard abort: status: not active Loading plan: status: Not available Price/performance table: status: Not available Transport Layer Security (TLS) status communication: not active DID 103A: supported number_evse_slac: 0 PLC_modem_status: not active number_slac_attemps: 0 DID 1033: no_active_link DID 1038: no_description DID 1039: supported Target HV charge current: 5.1 A Powerline communication: charging process status: Standby 3280897 - Charging Station B1AD0 F0 [01101101] - Identification Failed [ETHTRCV_30_AR7000_SLAC_STEP_1_SET_CCO_Timeout] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 39 Reset counter: 40 Mileage: 40068 km Date: 2023.12.29 Time: 18:45:06 DID 1DA0: AC main charge DID 1DAC: Charging Frequency: 1000 Hz Control voltage: 6104.0 mV Duty cycle: 16.1 % Activation charge cover lock charge socket A: not requested Lock for high-voltage charging connector: locked Status connect. recognition: detected Charge socket temperature sensor AC: 30.0 °C Temperature sensor 1: resistance value: 1100 Ohm DID 15E2: 9.0 °C DID 081C: 0 W DID 081D: 1 W DID 081E: 2278 W DID 0286: 13.4 V DID 497C: not active DID 537A: 14.3 V DID 1525: 3891 mV DID 4219: High voltage power off not recognized DID 5372: 8.0 °C No. of lockings: 3049 No. of connections: 147 Number of successful charging connector locks: 927 Wake-up counter: contact (proximity): 0 Wake-up counter: Control Pilot: 0 Charging standard abort: status: not active Loading plan: status: Not available Price/performance table: status: Not available Transport Layer Security (TLS) status communication: not active DID 103A: supported number_evse_slac: 0 PLC_modem_status: active number_slac_attemps: 3 DID 1033: SLAC_failed DID 1038: no_description DID 1039: supported Target HV charge current: 5.6 A Powerline communication: charging process status: Standby 3280899 - Charging Station B1AD0 F0 [01101101] - Identification Failed [ETHTRCV_30_AR7000_SLAC_STEP_3_PARAM_REQ_Timeout] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 1 Reset counter: 40 Mileage: 28891 km Date: 2023.05.15 Time: 15:18:08 DID 1DA0: AC main charge DID 1DAC: Charging Frequency: 1002 Hz Control voltage: 6049.0 mV Duty cycle: 50.9 % Activation charge cover lock charge socket A: not requested Lock for high-voltage charging connector: locked Status connect. recognition: detected Charge socket temperature sensor AC: 30.0 °C Temperature sensor 1: resistance value: 1090 Ohm DID 15E2: 18.0 °C DID 081C: 3 W DID 081D: 3538 W DID 081E: 3524 W DID 0286: 13.3 V DID 497C: not active DID 537A: 14.4 V DID 1525: 1966 mV DID 4219: High voltage power off not recognized DID 5372: 17.0 °C No. of lockings: 2198 No. of connections: 1 Number of successful charging connector locks: 699 Wake-up counter: contact (proximity): 0 Wake-up counter: Control Pilot: 0 Charging standard abort: status: not active Loading plan: status: Not available Price/performance table: status: Not available Transport Layer Security (TLS) status communication: not active DID 103A: supported number_evse_slac: 0 PLC_modem_status: active number_slac_attemps: 1 DID 1033: SLAC_active DID 1038: no_description DID 1039: supported Target HV charge current: 17.3 A Powerline communication: charging process status: Standby 5242881 - Communication Authentication U3035 00 [01100000] - Invalid Signal [SOK_signature_verification_failed] Intermittent - Not Confirmed - Tested Since Memory Clear 14750981 - Charging Socket 1 P1CF6 00 [01100000] - Unlock Prohibited [Plug_unlocking_error] Intermittent - Not Confirmed - Tested Since Memory Clear