Batt. Chrg. - 5QE 915 681 AT
Coding for Batt. Chrg. 5QE915681AT on Q7
5QE 915 681 AT
:H74 /
:2851
Coding: 11 50 8B 60 70 00
Coding: 11 50 8B 60 70 00
label:
5QE-915-681.clb
Faults: 4
Fault 2097922: Charging Socket A; Charging Plug Lock
: Mechanical Malfunction
: Mechanical Malfunction
Fault 13705551: Databus
: Missing Message
: Missing Message
Fault 2098960: HV System Deactivation
: Malfunction
: Malfunction
Fault 13705502: Databus
: Missing Message
: Missing Message
# |
Byte 0 [11]
/ Binary: 00010001 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
# |
Byte 1 [50]
/ Binary: 01010000 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
# |
Byte 2 [8B]
/ Binary: 10001011 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
# |
Byte 3 [60]
/ Binary: 01100000 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
# |
Byte 4 [70]
/ Binary: 01110000 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
# |
Byte 5 [00]
/ Binary: 00000000 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
Address C6: Batt. Chrg. (AX4) Labels:* 5QE-915-681.clb Part No SW: 5QE 915 681 AT HW: 5QE 915 681 AT Component: OBC Delta-ES H74 2851 Dataset Number: 4M0909811G 0001 Coding: 11508B607000 Shop #: WSC 31414 039 00001 ASAM Dataset: EV_OBCTwoPhaseDT2MLBev14P 001002 ROD: EV_OBCTwoPhaseDT2MLBev14P.rod VCID: 1E65DE65A0342B2A3DF-804A 4 Faults Found: 2097922 - Charging Socket A; Charging Plug Lock P33E8 00 [00001000] - Mechanical Malfunction Intermittent - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 2 Fault Frequency: 3 Reset counter: 129 Mileage: 64338 km Date: 2024.01.12 Time: 20:49:26 Activation charge cover unlock charge socket A: not requested Status charge cover lock charge socket A: not locked Activation charge cover lock charge socket A: not requested Connector unlocking requirement: 00000000 Connector locking requirement: 00000000 Lock for high-voltage charging connector: not locked Status connect. recognition: present Max. current of charge connector: 20 A Charge socket temperature sensor AC: 15.3 C Charge sensor temperature sensor DC: -55.0 C charger_coolant_temperature: 28 C Current: 15.9 A Frequency: 1000 Hz Control voltage: 8935 mV Duty cycle: 26.5 % Signal recognized: 00000001 13705551 - Databus U1121 00 [00001000] - Missing Message [Klima_14_Timeout] Intermittent - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 230 Reset counter: 131 Mileage: 63064 km Date: 2023.12.12 Time: 16:27:58 2098960 - HV System Deactivation P33F1 00 [00001000] - Malfunction Intermittent - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 1 Reset counter: 125 Mileage: 63975 km Date: 2024.01.10 Time: 13:24:52 Operational readiness in H-V system: active Status charge readiness: engine: operational Status charge readiness charge mngmt.: operational Act. voltage HV battery: 338.0 V Act. current HV battery: -511.0 A A/C requirement: no request Current condition of battery mgmt. system: External Charging Limit for charge current: 0 A Max. battery charging voltage: 348 V Battery temperature: 0.0 C 13705502 - Databus U1121 00 [00001000] - Missing Message [Einheiten_01_TimeOut] Intermittent - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 157 Reset counter: 131 Mileage: 63064 km Date: 2023.12.12 Time: 15:06:44