Back-up Cam - 1EA 980 556 J

Coding for Back-up Cam 1EA.980.556.J on Enyaq

1EA 980 556 J :H30 / :0397
Coding: 03  03  30  00  84  30  00 
label: None
Byte 0 [03] / Binary: 00000011
bit 0 1
bit 1 1
bit 2 0
bit 3 0
bit 4 0
bit 5 0
bit 6 0
bit 7 0
Byte 1 [03] / Binary: 00000011
bit 0 1
bit 1 1
bit 2 0
bit 3 0
bit 4 0
bit 5 0
bit 6 0
bit 7 0
Byte 2 [30] / Binary: 00110000
bit 0 0
bit 1 0
bit 2 0
bit 3 0
bit 4 1
bit 5 1
bit 6 0
bit 7 0
Byte 3 [00] / Binary: 00000000
bit 0 0
bit 1 0
bit 2 0
bit 3 0
bit 4 0
bit 5 0
bit 6 0
bit 7 0
Byte 4 [84] / Binary: 10000100
bit 0 0
bit 1 0
bit 2 1
bit 3 0
bit 4 0
bit 5 0
bit 6 0
bit 7 1
Byte 5 [30] / Binary: 00110000
bit 0 0
bit 1 0
bit 2 0
bit 3 0
bit 4 1
bit 5 1
bit 6 0
bit 7 0
Byte 6 [00] / Binary: 00000000
bit 0 0
bit 1 0
bit 2 0
bit 3 0
bit 4 0
bit 5 0
bit 6 0
bit 7 0
Address 6C: Back-up Cam. (J772)       Labels:* None
   Part No SW: 1EA 980 556 J    HW: 5WA 980 556 B
   Component: RV eCompact   H30 0397  
   Serial number: FCLK20140523010 Dataset Number: V03935351SL 0001
   Coding: 03033000843000
   ASAM Dataset: EV_CamSysRVCCompaFicosMEB 004014
   ROD: EV_CamSysRVCCompaFicosMEB_004_VWE3.rod
   VCID: 42DDB7CA5409A2CA59F-8016
 
1 Fault Found:
13705529 - Databus 
          U1121 00 {046} - Missing Message
          {message ORU_01 not received}
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 40
                    Mileage: 99 km
                    Date: 2023.07.13
                    Time: 10:47:21