Door Elect Pass - 3AA 959 702 A
Coding for Door Elect Pass 3AA959702A on Passat
3AA 959 702 A
:002 /
:0533
Coding: 02 00 B6
Coding: 02 00 B6
label:
3C0-959-70X-GEN4.clb
Faults: 6
Fault 65538: Local Data Bus
: No Communication
: No Communication
Fault 66048: Motor for Front Window Regulator
: Missing Calibration / Basic Setting
: Missing Calibration / Basic Setting
Fault 67330: Switch for Central Locking
: Signal Implausible
: Signal Implausible
Fault 67589: Turn Signal in Exterior Mirror
: Electrical Failure
: Electrical Failure
Fault 65793: Supply voltage
: Voltage too Low
: Voltage too Low
Fault 131329: Rear Door Control Module
: Supply Voltage too Low
: Supply Voltage too Low
# |
Byte 0 [02]
/ Binary: 00000010 |
---|---|
bit 0 | |
bit 1 | Start/Stop System active/installed [PR-7L6] |
bit 2 | Mode for PQ25 (instead PQ35) |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
# |
Byte 1 [00]
/ Binary: 00000000 |
---|---|
bit 0 | Seat Memory AND/OR Mirror with Memory Function installed |
bit 1 | Right-Hand-Drive (RHD) [PR-L0R] |
bit 2 | Safe-Motor NOT installed [PR-4I2/5C1] |
bit 3 | Pinch Protection inactive |
bit 4 | Folding Mirrors installed [PR-6XE/6XK] |
bit 5 | |
bit 6 | |
bit 7 |
# |
Byte 2 [B6]
/ Binary: 10110110 |
---|---|
bit 0 | Rear Lid Remote Unlock Button (E233) installed |
bit 1 | Ambient Mirror Illumination installed |
bit 2 | Mirror Turn Signals installed [STANDARD] |
bit 3 | Interior Door Handle Illumination installed [PR-QQ4/QQ6] |
bit 4 | Automatic Run active [STANDARD] |
bit 5 | Mirror Heater installed [PR-6XD/6XE/6XJ/6XK] |
bit 6 | Door Exit/Warning Light installed [PR-QQ4] |
bit 7 | Rear Door Control Modules installed |
Address 52: Door Elect, Pass. (J387) Labels:| 3C0-959-70X-GEN4.clb Part No SW: 3AA 959 702 A HW: 3C0 959 792 C Component: TUER-SG BT 002 0533 Revision: 14110009 Serial number: 0006736880 Coding: 0200B6 Shop #: WSC 05311 115 00000 ASAM Dataset: EV_TSGBPQ35BRFVW46X A04001 ROD: EV_TSGBPQ35BRFVW46X_VW32.rod VCID: 366393DF89477439AB-8062 6 Faults Found: 65538 - Local Data Bus U10BA 00 [009] - No Communication [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 4 Fault Frequency: 1 Reset counter: 0 Mileage: 453921 km Date: 2022.07.12 Time: 00:00:02 66048 - Motor for Front Window Regulator B11EC 54 [009] - Missing Calibration / Basic Setting Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 7 Fault Frequency: 4 Reset counter: 0 67330 - Switch for Central Locking B122D 29 [008] - Signal Implausible Intermittent - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 2 Fault Frequency: 7 Reset counter: 40 Mileage: 453921 km Date: 2022.07.04 Time: 21:41:30 67589 - Turn Signal in Exterior Mirror B11FD 01 [008] - Electrical Failure Intermittent - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 2 Fault Frequency: 1 Reset counter: 40 Mileage: 453921 km Date: 2022.07.11 Time: 02:16:11 65793 - Supply voltage U1011 00 [009] - Voltage too Low [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 2 Fault Frequency: 2 Reset counter: 40 Mileage: 453921 km Date: 2022.07.11 Time: 02:10:00 131329 - Rear Door Control Module B11ED F0 [008] - Supply Voltage too Low Intermittent - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 2 Fault Frequency: 1 Reset counter: 40 Mileage: 453921 km Date: 2022.07.11 Time: 02:12:31