Instruments - 3AA 920 880 H
Coding for Instruments 3AA920880H on Passat
3AA 920 880 H
:H05 /
:0505
Coding: 16 1F 01
Coding: 16 1F 01
label:
3C8-920-xxx-17.clb-SRI1
Faults: 8
Fault 9453330: Outside temperature sensor
: Resistance Too High
: Resistance Too High
Fault 9453842: Oil Level Thermal Sensor
: Signal High Time > Maximum
: Signal High Time > Maximum
Fault 13635840: Supply voltage
: Voltage too Low
: Voltage too Low
# |
Byte 0 [16]
/ Binary: 00010110 |
---|---|
bit 0 | |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4-7 |
# |
Byte 1 [1F]
/ Binary: 00011111 |
---|---|
bit 0 | Brakepad Warning active/installed |
bit 1 | Seatbelt Warning active/installed |
bit 2 | Washer Fluid Warning active/installed |
bit 3 | Multi-Function-Display active/installed |
bit 4 | Vehicle Symbol 'Wagon' (MY 2010+) active |
bit 5 | |
bit 6 | |
bit 7 |
# |
Byte 2 [01]
/ Binary: 00000001 |
---|---|
bit 0 | Tire Pressure Monitoring (TPMS) active/installed |
bit 1 | |
bit 2 | |
bit 3 | |
bit 4 | |
bit 5 | |
bit 6 | |
bit 7 |
Address 17: Instruments (J285) Labels:| 3C8-920-xxx-17.clb-SRI1 Part No SW: 3AA 920 880 H HW: 3AA 920 880 H Component: KOMBI H05 0505 Serial number: 00000000000000 Coding: 161F01 Shop #: WSC 05314 115 00000 ASAM Dataset: EV_Kombi_UDS_VDD_RM09 A04716 ROD: EV_Kombi_UDS_VDD_RM09_004_VW46.rod (VIN: N/A) VCID: 387F9DE783538249B9-806C 8 Faults Found: 9453330 - Outside temperature sensor B103F 1B [009] - Resistance Too High Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 2 Fault Frequency: 1 Reset counter: 0 Mileage: 453920 km Date: 2022.06.05 Time: 21:09:04 9453842 - Oil Level Thermal Sensor B1041 35 [009] - Signal High Time > Maximum Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 2 Fault Frequency: 1 Reset counter: 0 Mileage: 453921 km Date: 2022.06.08 Time: 00:00:19 12648448 - Function Restricted due to Missing Message(s) U1111 00 [009] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 6 Fault Frequency: 1 Reset counter: 0 Mileage: 453921 km Date: 2022.06.05 Time: 00:17:39 12656896 - Function Restricted due to Missing Message(s) U1111 00 [008] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Intermittent - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 6 Fault Frequency: 51 Reset counter: 40 Mileage: 453921 km Date: 2022.07.11 Time: 14:42:05 13638912 - Function Restricted due to Missing Message(s) U1111 00 [008] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Intermittent - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 6 Fault Frequency: 1 Reset counter: 40 Mileage: 453921 km Date: 2022.06.05 Time: 00:17:39 12718592 - Function Restricted due to Missing Message(s) U1111 00 [008] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Intermittent - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 6 Fault Frequency: 1 Reset counter: 40 Mileage: 453921 km Date: 2022.06.06 Time: 01:00:44 12658688 - Function Restricted due to Missing Message(s) U1111 00 [008] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Intermittent - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 6 Fault Frequency: 98 Reset counter: 40 Mileage: 453921 km Date: 2022.07.11 Time: 14:41:59 13635840 - Supply voltage U1011 00 [008] - Voltage too Low [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Intermittent - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Status: 00000001 Fault Priority: 6 Fault Frequency: 3 Reset counter: 40 Mileage: 453921 km Date: 2022.06.19 Time: 01:06:27