Byte 0 [00]
/ Binary: 00000000
|
bit 0-5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 1 [09]
/ Binary: 00001001
|
bit 0-2 |
|
bit 3 |
Extended Display Temperature Range active
|
bit 4 |
Function Light Dimming via Light Sensor active
|
bit 5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 2 [00]
/ Binary: 00000000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3-5 |
|
bit 6 |
|
bit 7 |
|
# |
Byte 3 [48]
/ Binary: 01001000
|
bit 0 |
|
bit 1 |
|
bit 2 |
|
bit 3 |
|
bit 4-6 |
|
bit 7 |
Blower/Display Logic for absolute Blower Voltage without Blower Stage Display
|
# |
Byte 4 [04]
/ Binary: 00000100
|
bit 0 |
|
bit 1-3 |
|
bit 4 |
|
bit 5 |
|
bit 6 |
Compressor Shutoff via Humidity Sensor active
|
bit 7 |
|
Address 08: Auto HVAC (J255) Labels: 5K0-907-044.clb
Part No SW: 3AA 907 044 AJ HW: 3AA 907 044 AJ
Component: Climatronic H03 0404
Revision: 00001K02
Coding: 0009004804
Shop #: WSC 00070 000 00000
ASAM Dataset: EV_Climatronic A01010
ROD: EV_ClimaAutoBasis_VW36.rod
VCID: F8BCA3AC435F71FEC6-80AC
1 Fault Found:
13701424 - Function Restricted due to Missing Message(s)
U1111 00 [009] - -
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 13
Reset counter: 18
Mileage: 258503 km
Date: 2018.09.29
Time: 12:53:07