Byte 0
[19]
/ Binary: 00011001
|
|
☑
bit 0
|
Selective Central Locking (Single Door Opening)
|
|
☐
bit 1
|
Central Locking without Safe-Function
|
|
☐
bit 2
|
Central Locking without sensible Safe-Function
|
|
☑
bit 3
|
Auto-Unlock (unlocking after removing key from ignition)
|
|
☑
bit 4
|
Auto-Lock (automatic locking from 15 km/h)
|
|
☐
bit 5
|
Central Locking with intentional use of Safe-Function
|
|
☐
bit 6
|
Central Locking Switch Rear activate total Locking
|
|
☐
bit 7
|
|
Byte 1
[E8]
/ Binary: 11101000
|
|
☐
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
Central Locking (Rear Lid) 2-Motors Lock installed
|
|
☑
bit 3
|
Central Locking (Rear Lid) interior Switch via CAN
|
|
☐
bit 4
|
Central Locking (Rear Lid) Softtouch (direct open/no release)
|
|
☑
bit 5
|
Central Locking (Rear Lid) Switch controlled
|
|
☑
bit 6
|
Central Locking (Rear Lid) Central Locking Actuator installed
|
|
☑
bit 7
|
Central Locking (Rear Lid) Part of Central Locking
|
Byte 2
[02]
/ Binary: 00000010
|
|
☐
bit 0
|
North American Lock Type (without SAFE Motor)
|
|
☑
bit 1
|
Central Locking (Rear Lid) "Security Lock"
|
|
☐
bit 2
|
Central Locking (Fond) 1-Motor Lock installed
|
|
☐
bit 3
|
Central Locking (Rear Lid) 1-Motor Lock installed
|
|
☐
bit 4
|
Central Locking (Rear Lid) Rear Window Actuator Switch controlled
|
|
☐
bit 5
|
Central Locking (Rear Lid) Actuator for Rear Window installed
|
|
☐
bit 6
|
Central Locking with selective Locking plus Drivers Door
|
|
☐
bit 7
|
Central Locking (Rear) Locking for Roof/Rear Lid Cover (Cabrio)
|
Byte 3
[48]
/ Binary: 01001000
|
|
☐
bit 0
|
Comfort Function inactive
|
|
☐
bit 1
|
Comfort Function Power Windows/Sunroof via Drivers Door Lock inactive
|
|
☐
bit 2
|
Comfort Function Power Windows/Sunroof via Passengers Door Lock inactive
|
|
☑
bit 3
|
Comfort Function Power Windows/Sunroof via Rear Lid Door Lock inactive
|
|
☐
bit 4
|
Comfort Function Power Windows/Sunroof via Power Window Switch inactive
|
|
☐
bit 5
|
Comfort Function Power Windows/Sunroof via Remote Control inactive
|
|
☑
bit 6
|
Comfort Function automatic Closing
|
|
☐
bit 7
|
Power Windows/Sunroof disabled after door Opening
|
Byte 4
[7F]
/ Binary: 01111111
|
|
☑
bit 0
|
Comfort Opening Power Windows via Door Lock active
|
|
☑
bit 1
|
Comfort Opening Power Windows via Power Window Switch active
|
|
☑
bit 2
|
Comfort Opening Power Windows via Remote Control active
|
|
☑
bit 3
|
Comfort Closing Power Windows via Door Lock active
|
|
☑
bit 4
|
Comfort Closing Power Windows via Power Window Switch active
|
|
☑
bit 5
|
Comfort Closing Power Windows via Remote Control active
|
|
☑
bit 6
|
Comfort Function after authorized Access only for a limited Time
|
|
☐
bit 7
|
|
Byte 5
[2D]
/ Binary: 00101101
|
|
☑
bit 0
|
Comfort Opening Sunroof via Door Lock active
|
|
☐
bit 1
|
Comfort Opening Sunroof via Power Window Switch active
|
|
☑
bit 2
|
Comfort Opening Sunroof via Remote Control active
|
|
☑
bit 3
|
Comfort Closing Sunroof via Door Lock active
|
|
☐
bit 4
|
Comfort Closing Sunroof via Power Window Switch active
|
|
☑
bit 5
|
Comfort Closing Sunroof via Remote Control active
|
|
☐
bit 6
|
Comfort Opening Type for Sunroof (0 = open/ 1 = lift)
|
|
☐
bit 7
|
|
Byte 6
[84]
/ Binary: 10000100
|
|
☐
bit 0
|
Unlocking Confirmation (Blink) via Door Locks
|
|
☐
bit 1
|
Unlocking Confirmation (Horn) via Door Locks
|
|
☑
bit 2
|
Unlocking Confirmation (Blink) via Remote Control
|
|
☐
bit 3
|
Unlocking Confirmation (Horn) via Remote Control
|
|
☐
bit 4
|
|
|
☐
bit 5
|
|
|
☐
bit 6
|
|
|
☑
bit 7
|
Horn Confirmation Configuration blocked
|
Byte 7
[04]
/ Binary: 00000100
|
|
☐
bit 0
|
Locking Confirmation (Blink) via Door Locks
|
|
☐
bit 1
|
Locking Confirmation (Horn) via Door Locks
|
|
☑
bit 2
|
Locking Confirmation (Blink) via Remote Control
|
|
☐
bit 3
|
Locking Confirmation (Horn) via Remote Control
|
|
☐
bit 4
|
|
|
☐
bit 5
|
|
|
☐
bit 6
|
|
|
☐
bit 7
|
|
Byte 8
[C8]
/ Binary: 11001000
|
|
☐
bit 0
|
Remote Control inactive
|
|
☐
bit 1
|
Remote Control with "Terminal 15 ON" inactive
|
|
☐
bit 2
|
Remote Control Range Limitation active
|
|
☑
bit 3
|
Manual Remote Control learning/unlearning active
|
|
☐
bit 4
|
|
|
☐
bit 5
|
|
|
☑
bit 6
|
Anti-Theft-System Activation Confirmation (Blink)
|
|
☑
bit 7
|
Anti-Theft-System Activation Confirmation (Horn)
|
Byte 9
[4F]
/ Binary: 01001111
|
|
☑
bit 0
|
Doors (0 = 2-doors / 1 = 4-doors)
|
|
☑
bit 1
|
Front Power Windows installed
|
|
☑
bit 2
|
Rear Power Windows installed
|
|
☑
bit 3
|
Central Locking installed
|
|
☐
bit 4
|
Model (0 = Left-Hand-Drive/ 1 = Right-Hand-Drive)
|
|
☐
bit 5
|
|
|
☑
bit 6
|
Synchronised Mirror Adjustment
|
|
☐
bit 7
|
Mirror Lowering with Reverse Rear (only with Memory Seats)
|
Byte 10
[00]
/ Binary: 00000000
|
|
☐
bit 0
|
Anti-Theft System deactivated
|
|
☐
bit 1
|
Anti-Theft System disarming only via Remote Control or Immobilizer
|
|
☐
bit 2
|
Anti-Theft active with intentional de-safe / Interior Monitoring inactive
|
|
☐
bit 3
|
Anti-Theft Alarm Delay (15 sec) inactive (Thatcham)
|
|
☐
bit 4
|
|
|
☐
bit 5
|
Anti-Theft System passive arming
|
|
☐
bit 6
|
Inclination Sensor installed
|
|
☐
bit 7
|
Interior Monitoring installed
|
Byte 11
[00]
/ Binary: 00000000
|
|
☐
bit 0
|
|
|
☐
bit 1
|
|
|
☐
bit 2
|
|
|
☐
bit 3
|
|
|
☐
bit 4
|
Siren installed
|
|
☐
bit 5
|
Siren Tone Type (0 = frequency modulated / 1 = discontinuoud)
|
|
☐
bit 6
|
Siren Alarm Type (0 = 10 Alarms (GB/Irland) / 1 = 1 Alarm (RoW))
|
|
☐
bit 7
|
Siren Configuration blocked
|
Address 46: Central Conv. Labels: 1K0-959-433-MIN.clb
Part No: 1K0 959 433 C
Component: KSG 0201
Coding: 19E802487F2D8404C84F0000
Shop #: WSC 01279 785 00200
VCID: 30650880A3DD929E243-8065