Therm. mgt. - 4M0 965 429 P

Coding for Therm. mgt. 4M0965429P on Q7

4M0 965 429 P :H08 / :0304
Coding: 00 
label: None
Faults: 0
# Byte 0 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Address C5: Therm. mgt. (J1024)       Labels:* None
   Part No SW: 4M0 965 429 P    HW: 4M0 965 429 F
   Component: TME-Max       H08 0304  
   Serial number: 0173610 Dataset Number: 4M0909476L  0028
   Coding: 00
   Shop #: WSC 31414 039 00001
   ASAM Dataset: EV_ThermContrVISAU49X 002036
   ROD: EV_ThermContrVISAU49X_002_AU49.rod
   VCID: 44D14C0D6E1821FA4BB-8010
 
   A/C pressure/coolant temperature sensor: 
   Subsystem 1 - Part No SW: 4M0 959 603 C    HW: 4M0 959 603 C
   Component: G395 pT-Sens1  H11 0010 
 
   Auxiliary Air Heater Control Module/PTC: 
   Subsystem 2 - Part No SW: 12E 963 231 G    HW: 12E 963 231 G
   Component: J848 HV-PTC  H09 0208 
   Serial number: LR192363003810000240
 
   A/C compressor sub: 
   Subsystem 3 - Part No SW: 4G0 816 797 D    HW: 4G0 816 797 D
   Component: J842 EKK es33  H04 0016 
   Serial number: 00000000020040700537
 
   A/C pressure/coolant temperature sensor 2: 
   Subsystem 4 - Part No SW: 4M0 959 603 C    HW: 4M0 959 603 C
   Component: G826 pT-Sens2  H11 0010 
 
   Expansion valve 2 for refrigerant: 
   Subsystem 5 - Part No SW: 4M0 816 682 E    HW: 4M0 816 682 E
   Component: N637 EV2_KaMi  H12 0102 
   Serial number: 00000000000151408034
 
1 Fault Found:
60016 - Interior Pre-Conditioning 
          P13F1 00 [00101000] - Not Started
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 2
                    Mileage: 63366 km
                    Date: 2023.12.15
                    Time: 18:24:10
 
                    Unlearning counter according OBD: 25
                    Expanded ambient data 1-Voltage terminal 30: 0.000 V
                    Expanded ambient data 1-Vehicle speed: 0 km/h
                    Expanded ambient data 1-System status: Control operation: ignition on
                    Expanded ambient data 1-Power quota setting by energy management: 00
                    Expanded ambient data 1-Status of drive readiness hybrid: Engine start
                    Expanded ambient data 1-Ambient temperature: 9.00  C
                    Expanded ambient data 1-current state of low temp.circ.: 00
                    Expanded ambient data 1-previous state low-temp.circ.: 00
                    Expanded ambient data 1-Operating time in the current state of the low temp.circ.: 00
                    Expanded ambient data 1-current state of high-temp.circ.: 00
                    Expanded ambient data 1-previous state of high-temp.circ.: 00
                    Expanded ambient data 1-Operating time in the current state of the high temp.circ.: 00
                    Expanded ambient data 1-current state of battery low temp.circ.: 07
                    Expanded ambient data 1-previous state of battery low temp.circ.: 00
                    Expanded ambient data 1-Operating time in current state of the battery low temp.circ.: FF
                    Expanded ambient data 1-current state of battery cold circuit: 00
                    Expanded ambient data 1-previous state of battery cold circuit: 00
                    Expanded ambient data 1-Operating time in the current state of the cold circuit: FF
                    Switch-off conditions for pre-conditioning of interior-HV energy management: active
                    Switch-off conditions for pre-conditioning of interior-Function canceled: entry in DTC memory: not active
                    Switch-off conditions for pre-conditioning of interior-Communication malfunction: not active
                    Switch-off conditions for pre-conditioning of interior-Switch-off due to energy management: not active
                    Switch-off conditions for pre-conditioning of interior-No release by coordinator: active
                    Switch-off conditions for pre-conditioning of interior-Fuel supply low: not active
                    Switch-off conditions for pre-conditioning of interior-Over The Air Update: not active
                    Switch-off conditions for pre-conditioning of interior-Critical component temperature: not active
                    Switch-off conditions for pre-conditioning of interior-Parking heater error value received: not active