ParkSteer Assist - 3AA 919 475 L

Coding for ParkSteer Assist 3AA919475L on Passat

3AA 919 475 L :H06 / :0025
Coding: 35  91  05 
label: 3AA-919-475.clb
Faults: 3
Fault 13637393: Databus
: Received Error Message
Fault 13637392: Databus
: Received Error Message
Fault 13637395: Databus
: Received Error Message
# Byte 0 [35] / Binary: 00110101
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5-6
bit 7  
# Byte 1 [91] / Binary: 10010001
bit 0   Automatic Transmission installed
bit 1   Start/Stop System installed
bit 2  
bit 3  
bit 4   Right-Hand-Drive (RHD)
bit 5  
bit 6   Automated Rear Lid installed
bit 7   Mute Function active
# Byte 2 [05] / Binary: 00000101
bit 0-7
Address 10: Park/Steer Assist (J791)       Labels:| 3AA-919-475.clb
   Part No SW: 3AA 919 475 L    HW: 4H0 919 475 E
   Component: PARKHILFE PLA H06 0025  
   Revision: --------    Serial number: 56261127403008
   Coding: 359105
   Shop #: WSC 30024 959 101054
   ASAM Dataset: EV_EPHVA2C000000000 002008
   ROD: EV_EPHVA2C000000000.rod
   VCID: 4487495BCF8689AFA6-8010
 
3 Faults Found:
13637393 - Databus 
          U1123 00 [009] - Received Error Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 179
                    Mileage: 130421 km
                    Date: 2022.03.26
                    Time: 10:11:51
 
13637392 - Databus 
          U1123 00 [009] - Received Error Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 179
                    Mileage: 130421 km
                    Date: 2022.03.26
                    Time: 10:11:51
 
13637395 - Databus 
          U1123 00 [009] - Received Error Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 179
                    Mileage: 130421 km
                    Date: 2022.03.26
                    Time: 10:11:51