Auto HVAC 5E0 907 044 AS coding and module information (5E0907044AS)

Coding for Auto HVAC 5E0907044AS / 5E0907044AS

5E0 907 044 AS :H04 / :2002
Coding: 02  01  01  04  00  21  10  01  10  05  00  4D  00  10  10  22 

label: 5G0-907-044.clb
# Byte 0 [02] / Binary: 00000010
bit 0-3
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 1 [01] / Binary: 00000001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 2 [01] / Binary: 00000001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 3 [04] / Binary: 00000100
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 4 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6-7
# Byte 5 [21] / Binary: 00100001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 6 [10] / Binary: 00010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 7 [01] / Binary: 00000001
bit 0   Climate Modes active/displayed
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 8 [10] / Binary: 00010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 9 [05] / Binary: 00000101
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-5
bit 6  
bit 7  
# Byte 10 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 11 [4D] / Binary: 01001101
bit 0  
bit 1  
bit 2-3
bit 4   Frequency Shift for Blower Control Module active
bit 5  
bit 6   Blower Status Display in Auto-Mode active
bit 7  
# Byte 12 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 13 [10] / Binary: 00010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-5
bit 6  
bit 7  
# Byte 14 [10] / Binary: 00010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 15 [22] / Binary: 00100010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Address 08: Auto HVAC (J255)       Labels:| 5G0-907-044.clb
   Part No SW: 5E0 907 044 AS    HW: 5E0 907 044 AS
   Component: Climatronic   H04 2002  
   Revision: 00001K00    
   Coding: 02010104002110011005004D00101022
   Shop #: WSC 73430 031 00063
   ASAM Dataset: EV_ACClimaBHBVW37X 006147
   ROD: EV_ACClimaBHBVW37X_006_VW37.rod
   VCID: 76B5E6C56844C36A05F-8022
 
   Fresh air blower control module (front): 
 
   A/C pressure/coolant temperature sensor: 
 
   Air quality sensor: 
 
2 Faults Found:
262658 - High Pressure Sensor 
          B10AE 31 [00001000] - No Signal
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 218
                    Mileage: 232833 km
                    Date: 2024.01.20
                    Time: 17:30:39
 
                    Outside temperature: -1.5 °C
                    Engine RPM: 1000 /min
                    Compressor current: actual value: 0.000 A
                    Temperature downstream of evaporator: 5.3 °C
                    System run time-Engine running time: 255 s
                    System run time-Terminal 15 on: 255 s
 
1048835 - Functionality limited due to Engine Control Module 
          P1719 00 [00001000] - -
          [PTC-Reduzierung durch MSG]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 216
                    Mileage: 232679 km
                    Date: 2024.01.19
                    Time: 18:08:11
 
                    Voltage terminal 30: 13.6 V
                    Auxiliary heater: in stages-Enabling for auxiliary heater operation: Enabling stage 3
                    Auxiliary heater: in stages-Act.val.: 2
                    Auxiliary heater: in stages-Target value: 3
                    Auxiliary heater: in stages-Specified value for control: 3