Address C6: Batt. Chrg. (J1050) Labels:| 1EA-915-684.clb
Part No SW: 1EA 915 684 GG HW: 1EA 915 684 DK
Component: HV_CHARGER H65 2022
Serial number: 93373WE8000K6
Coding: 3080
ASAM Dataset: EV_OCCXPhase1KLOMEB01B 002019
ROD: EV_OCCXPhase1KLOMEB01B.rod
VCID: 865E7D52E8D4346AA5F-81D2
2 Faults Found:
3280899 - Charging Station
B1AD0 F0 {109} - Identification Failed
{ETHTRCV_30_AR7000_SLAC_STEP_3_PARAM_REQ_Timeout}
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 1
Reset counter: 40
Mileage: 16 km
Date: 2023.07.19
Time: 14:16:26
DID 1DA0: Standby
DID 1DAC: Standby
Frequency: 999 Hz
Control voltage: 5980.0 mV
Duty cycle: 66.1 %
Activation charge cover lock charge socket A: not requested
Lock for high-voltage charging connector: locked
Status connect. recognition: detected
Charge socket temperature sensor AC: 30.0 °C
Temperature sensor 1: resistance value: 1035 Ohm
DID 15E2: 25.0 °C
DID 081C: 0 W
DID 081D: 0 W
DID 081E: 0 W
DID 0286: 14.5 V
DID 497C: active
DID 537A: 14.2 V
DID 1525: 1508 mV
DID 4219: High voltage power off not recognized
DID 5372: 25.0 °C
No. of lockings: 1
No. of connections: 1
Number of successful charging connector locks: 1
Wake-up counter: contact (proximity): 0
Wake-up counter: Control Pilot: 0
Charging standard abort: status: not active
Loading plan: status: Not available
Price/performance table: status: Not available
Transport Layer Security (TLS) status communication: not active
DID 103A: supported
number_evse_slac: 0
PLC_modem_status: active
number_slac_attemps: 1
DID 1033: SLAC_active
DID 1038: no_description
DID 1039: supported
Target HV charge current: 0.0 A
Powerline communication: charging process status: Standby
14750981 - Charging Socket 1
P1CF6 00 {096} - Unlock Prohibited
{Plug_unlocking_error}
Intermittent - Not Confirmed - Tested Since Memory Clear