Antenna - 1EA 035 741 G

Coding for Antenna 1EA035741G on ID.3

1EA 035 741 G :H07 / :0221
Coding: 02  31  06  11  04  02  80 
label: None
Faults: 3
Fault 1375744: Secure Onboard Communication
: Signature Verification Failed
Fault 0081: Databus
: Missing Message
Fault 0082: Ethernet Databus
: Missing Message from Emergency Call Module
# Byte 0 [02] / Binary: 00000010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 1 [31] / Binary: 00110001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 2 [06] / Binary: 00000110
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 3 [11] / Binary: 00010001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 4 [04] / Binary: 00000100
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 5 [02] / Binary: 00000010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 6 [80] / Binary: 10000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Address 8107: Antenna (J666)       Labels:* None
   Part No SW: 1EA 035 741 G    HW: 1EA 035 741 D
   Component: TrxModulHigh  H07 0221  
   Serial number: 0000000107VIFW2
   Coding: 02310611040280
   ASAM Dataset: EV_TrxMLGEMEB 006014
   ROD: EV_TrxMLGEMEB.rod
   VCID: 323E104324A066BAE97-8066 SFD
 
3 Faults Found:
1375744 - Secure Onboard Communication 
          U14FE 00 [00101000] - Signature Verification Failed
          [SOK_signature_verification_failed]
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Priority: 1
                    Fault Frequency: 1
                    Reset counter: 36
                    Mileage: 42428 km
                    Date: 2024.02.06
                    Time: 16:52:05
 
                    Failed verification status: valid
                    Number of failed verifications: 10
                    Verification failed: 00 15
 
0081 - Databus 
          U1121 00 [01100000] - Missing Message
          [Ethernet-Datenbus - fehlende Botschaft- POS_GNSS_05_Position]
          Intermittent - Not Confirmed - Tested Since Memory Clear
 
0082 - Ethernet Databus 
          U1540 00 [01100000] - Missing Message from Emergency Call Module
          [Ethernet-Datenbus - fehlende Botschaft vom Notrufmodul]
          Intermittent - Not Confirmed - Tested Since Memory Clear