Address 08: Auto HVAC (J301) Labels:| 5G0-907-426.clb
Part No SW: 5GM 907 426 A HW: 5GM 907 426 A
Component: AC Manuell H02 1001
Revision: 00001K01
Coding: 02020104202100000000000000000000
Shop #: WSC 01383 790 50316
ASAM Dataset: EV_ACManueBHBVW37X 003019
ROD: EV_ACManueBHBVW37X_003.rod
VCID: 46838AB8F93FA3B669-8012
Fresh Air Blower Front:
Geber für Kältemitteldruck/Kältemitteltemperatur:
3 Faults Found:
1048834 - Functional Limitation due to Energy Management
B10CD 00 [008] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 7
Fault Frequency: 5
Reset counter: 212
Mileage: 185007 km
Date: 2020.10.02
Time: 06:33:03
Voltage terminal 30: 13.4 V
Auxiliary heater: in stages-Enabling for auxiliary heater operation: No enabling
Auxiliary heater: in stages-Act.val.: 1
Auxiliary heater: in stages-Specified value: 3
Auxiliary heater: in stages-Specified value for control: 3
1048835 - Functionality limited due to Engine Control Module
P1719 00 [008] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 8
Reset counter: 210
Mileage: 185195 km
Date: 2020.10.05
Time: 05:46:29
Voltage terminal 30: 13.4 V
Auxiliary heater: in stages-Enabling for auxiliary heater operation: Enabling stage 3
Auxiliary heater: in stages-Act.val.: 3
Auxiliary heater: in stages-Specified value: 3
Auxiliary heater: in stages-Specified value for control: 3
1048836 - Blower Output Reduction due to Energy Management
B10CE 00 [008] - -
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 15
Reset counter: 212
Mileage: 183722 km
Date: 2020.09.21
Time: 07:02:25
Voltage terminal 30: 14.3 V
CAN input signal(s) status-Transport mode: On
CAN input signal(s) status-Static current measuring mode: OFF
CAN input signal(s) status-Windshield wiper: OFF
CAN input signal(s) status-Energy management deactivation stage: Deactivation stage 0
CAN input signal(s) status-Wipe wash: OFF
CAN input signal(s) status-Rear window heater actual value: OFF
CAN input signal(s) status-Back-up light: OFF
CAN input signal(s) status-Actual value of windshield heater: OFF