Information Electr 3G0 035 047 coding and module information (3G0035047)

Coding for Information Electr 3G0035047 / 3G0035047

3G0 035 047 :043 / :0344
Coding: 02  73  00  02  00  00  00  00  11  52  00  02  00  0D  0E  00  2F  01  00  F4  71  F1  07  00  CF 

label: 5G0-035-MIB-HGH2.clb
# Byte 0 [02] / Binary: 00000010
bit 0-23
# Byte 1 [73] / Binary: 01110011
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 2 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 3 [02] / Binary: 00000010
bit 0-7
# Byte 4 [00] / Binary: 00000000
bit 0-31
# Byte 5 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 6 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 7 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 8 [11] / Binary: 00010001
bit 0   Microphone 1 connected [PR-UE4/UI2/UI4]
bit 1  
bit 2  
bit 3  
bit 4   AUX-IN Connection active [PR-UE4/UI2/UI4]
bit 5  
bit 6   VDA Low Frequency Input active
bit 7  
# Byte 9 [52] / Binary: 01010010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 10 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 11 [02] / Binary: 00000010
bit 0-7
# Byte 12 [00] / Binary: 00000000
bit 0-3
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 13 [0D] / Binary: 00001101
bit 0   RDS HMI Switch active
bit 1  
bit 2  
bit 3   Radio Text Plus (RT+) active [STANDARD]
bit 4   PI Ignore active
bit 5  
bit 6  
bit 7   DAB Alarm Announcement active [PR-QV3]
# Byte 14 [0E] / Binary: 00001110
bit 0  
bit 1   AM-Band Hide Switch active
bit 2  
bit 3   Multiple Entry Switch active
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 15 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4   Telephone Module / Network Access Device (NAD) active [PR-9ZK]
bit 5  
bit 6  
bit 7  
# Byte 16 [2F] / Binary: 00101111
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-5
bit 6  
bit 7  
# Byte 17 [01] / Binary: 00000001
bit 0-7
# Byte 18 [00] / Binary: 00000000
bit 0-7
# Byte 19 [F4] / Binary: 11110100
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6-7
# Byte 20 [71] / Binary: 01110001
bit 0   Display 1 installed/connected
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 21 [F1] / Binary: 11110001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5   Messaging via MAP active
bit 6  
bit 7  
# Byte 22 [07] / Binary: 00000111
bit 0   Instrument Cluster Graphics [STANDARD]
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 23 [00] / Binary: 00000000
bit 0   Speller Function active
bit 1  
bit 2   Legal Disclaimer active
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 24 [CF] / Binary: 11001111
bit 0   Emergency Call active/installed
bit 1   Speech Dialog System (SDS) active/installed [PR-QH1/QH8]
bit 2   Navigation Function active/installed [PR-7UG]
bit 3   WIFI Function active/installed [PR-9IE/9ZK]
bit 4   Multi Media Import (COPY) active
bit 5   Multi Media Import (RIPPING) active
bit 6   Traffic Sign Display (VZA) active
bit 7   Predictive Route Data (PSD) active
Address 5F: Information Electr. (J794)       Labels:| 5G0-035-MIB-HGH2.clb
   Part No SW: 3G0 035 047     HW: 3G0 035 047 
   Component: MU-H-NS-US    043 0344  
   Serial number: A265C0GB000224
   Coding: 027300020000000011520002000D0E002F0100F471F10700CF
   Shop #: WSC 12345 123 61029
   ASAM Dataset: EV_MUHig4CGen2HBAS 001001
   ROD: EV_MUHig4CGen2HBAS_VW37.rod
   VCID: 5DE490940DB2ECAF233-8008
 
   Operating And Display Unit 1: 
   Subsystem 1 - Part No SW: 5G0 919 606     HW: 5G0 919 606 
   Component: ABT_High  H62 0031 
   Serial number: VWZ8Z9RU30256Z      
 
   Data medium: 
   Subsystem 2 - Part No SW: V03 959 803 EE    HW: -----------
   Component: NAR 2017  --- 0057 
   Serial number: --------------------
 
9 Faults Found:
1555 - Check Software Version Management 
          B201A 00 [009] -  - 
          [Check software version management]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 167
                    Mileage: 54356 km
                    Date: 2017.11.13
                    Time: 20:51:44
 
                    Voltage terminal 30: 14.1 V
                    Status_Software_Version_Management-module_name: ADUV101/ABT     
 
1556 - Internal Control Module Memory Check Sum Error 
          B2000 87 [009] - Missing message
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 167
                    Mileage: 54356 km
                    Date: 2017.11.13
                    Time: 20:51:57
 
                    Voltage terminal 30: 14.2 V
                    Software module: status-SW_Status_Consistency: 00 80 00
                    Software module: status-SW_Status_Device:              
 
13697024 - Component Protection 
          U1100 00 [009] - No Basic Setting
          [Anti-theft protection - component protection: no basic setting or basic setting incorrect]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 4
                    Fault Frequency: 1
                    Reset counter: 167
                    Mileage: 54356 km
                    Date: 2017.11.13
                    Time: 20:51:39
 
                    Voltage terminal 30: 14.2 V
 
15361024 - Component Protection 
          U1101 00 [009] - Active
          [Anti-theft protection - component protection active (0xEA6400)]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 4
                    Fault Frequency: 1
                    Reset counter: 167
                    Mileage: 54356 km
                    Date: 2017.11.13
                    Time: 20:51:39
 
                    Voltage terminal 30: 14.2 V
 
2571 - Navigation system 
          U902652 F2 [009] - Navigation database not enabled
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 167
                    Mileage: 54356 km
                    Date: 2017.11.13
                    Time: 20:51:40
 
                    Voltage terminal 30: 14.1 V
 
7170 - Function Restricted due to Missing Message(s) 
          U1111 00 [009] - -
          [A/C system (0x02) - function restriction due to communication error - BapErr_retry not successful]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 167
                    Mileage: 54356 km
                    Date: 2017.11.13
                    Time: 20:51:41
 
                    Voltage terminal 30: 14.1 V
                    BAP-BAP_Function_ID: 02
 
7191 - Function Restricted due to Missing Message(s) 
          U1111 00 [009] - -
          [Driving mode selection (0x17) - function restriction due to communication error - BapErr_retry not successful]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 167
                    Mileage: 54356 km
                    Date: 2017.11.13
                    Time: 20:51:41
 
                    Voltage terminal 30: 14.1 V
                    BAP-BAP_Function_ID: 02
 
7193 - Function Restricted due to Missing Message(s) 
          U1111 00 [009] - -
          [Lane departure warning: heading control (0x19) - function restriction due to communication error - BapErr_retry not successful]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 167
                    Mileage: 54356 km
                    Date: 2017.11.13
                    Time: 20:51:41
 
                    Voltage terminal 30: 14.1 V
                    BAP-BAP_Function_ID: 02
 
7194 - Function Restricted due to Missing Message(s) 
          U1111 00 [009] - -
          [Side assist (0x1A) - function restriction due to communication error - BapErr_retry not successful]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 167
                    Mileage: 54356 km
                    Date: 2017.11.13
                    Time: 20:51:41
 
                    Voltage terminal 30: 14.1 V
                    BAP-BAP_Function_ID: 02