Trunk Elect - 7N0 959 107 G

Coding for Trunk Elect 7N0959107G on Superb II

7N0 959 107 G :H12 / :0250
Coding: 07  33  33  C0  02 
label: 7N0-959-107.clb
Faults: 3
Fault 0056: Pinch Protection Strip 1
: Open Circuit
Fault 0059: Pinch Protection Strip 2
: Open Circuit
# Byte 0 [07] / Binary: 00000111
bit 0-7
# Byte 1 [33] / Binary: 00110011
bit 0  
bit 1  
bit 2-4
bit 5   Tone Generator installed
bit 6   Clutch installed
bit 7  
# Byte 2 [33] / Binary: 00110011
bit 0  
bit 1-2
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 3 [C0] / Binary: 11000000
bit 0-2
bit 3  
bit 4  
bit 5  
bit 6   Support for Transport Mode Function active
bit 7  
# Byte 4 [02] / Binary: 00000010
bit 0   Trailer Recognition installed [PR-1D2]
bit 1   Two-Sided Motor Sensor(s) installed
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Address 6D: Trunk Elect. (J605)       Labels:| 7N0-959-107.clb
   Part No SW: 7N0 959 107 G    HW: 7N0 959 107 A
   Component: HDSG-Modul    H12 0250  
   Revision: 41012002    Serial number: 246000745
   Coding: 073333C002
   Shop #: WSC 00000 000 00000
   ASAM Dataset: EV_HDSGVW428 201138
   ROD: EV_HDSGVW428_SK46.rod
   VCID: 3B7F3133B272BF5E06-806E
 
3 Faults Found:
0004 - No Basic Setting 
          B2010 00 [137] - -
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          MIL ON - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 1
                    Fault Frequency: 1
                    Reset counter: 59
                    Mileage: 193160 km
                    Date: 2020.11.13
                    Time: 10:33:49
 
                    Voltage terminal 30: 11.99 V
 
0056 - Pinch Protection Strip 1 
          B11DB 13 [137] - Open Circuit
          MIL ON - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 3
                    Fault Frequency: 1
                    Reset counter: 59
                    Mileage: 193160 km
                    Date: 2020.11.13
                    Time: 10:33:49
 
                    Voltage terminal 30: 11.99 V
 
0059 - Pinch Protection Strip 2 
          B11DC 13 [137] - Open Circuit
          MIL ON - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 3
                    Fault Frequency: 1
                    Reset counter: 59
                    Mileage: 193160 km
                    Date: 2020.11.13
                    Time: 10:33:49
 
                    Voltage terminal 30: 11.99 V