Auto HVAC 5G0 907 044 FD coding and module information (5G0907044FD)

Coding for Auto HVAC 5G0907044FD / 5G0907044FD

5G0 907 044 FD :H04 / :2201
Coding: 06  02  00  04  20  01  10  0D  11  05  00  00  00  10  10  36 

label: 5G0-907-044.clb
# Byte 0 [06] / Binary: 00000110
bit 0-3
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 1 [02] / Binary: 00000010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 2 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 3 [04] / Binary: 00000100
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 4 [20] / Binary: 00100000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6-7
# Byte 5 [01] / Binary: 00000001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 6 [10] / Binary: 00010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 7 [0D] / Binary: 00001101
bit 0   Climate Modes active/displayed
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 8 [11] / Binary: 00010001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 9 [05] / Binary: 00000101
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-5
bit 6  
bit 7  
# Byte 10 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 11 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2-3
bit 4   Frequency Shift for Blower Control Module active
bit 5  
bit 6   Blower Status Display in Auto-Mode active
bit 7  
# Byte 12 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 13 [10] / Binary: 00010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-5
bit 6  
bit 7  
# Byte 14 [10] / Binary: 00010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 15 [36] / Binary: 00110110
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Address 08: Auto HVAC (J255)       Labels:| 5G0-907-044.clb
   Part No SW: 5G0 907 044 FD    HW: 5G0 907 044 FD
   Component: Climatronic   H04 2201  
   Revision: 00001K10    
   Coding: 060200042001100D1105000000101036
   Shop #: WSC 00020 999 00000
   ASAM Dataset: EV_ACClimaBHBVW37X 006150
   ROD: EV_ACClimaBHBVW37X_006.rod
   VCID: EE90BA383136B53FC5-80BA
 
   Fresh Air Blower Front: 
 
   Geber fьr Kдltemitteldruck/Kдltemitteltemperatur: 
 
   Air quality sensor: 
 
1 Fault Found:
1048838 - Functional Limitation due to Energy Management 
          B10CD 00 [008] - -
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 92
                    Mileage: 330 km
                    Date: 2019.11.14
                    Time: 12:49:49
 
                    Voltage terminal 30: 11.8 V
                    CAN input signal(s) status-Transport mode: On
                    CAN input signal(s) status-Static current measuring mode: OFF
                    CAN input signal(s) status-Windshield wiper: OFF
                    CAN input signal(s) status-Energy management deactivation stage: Deactivation stage 1
                    CAN input signal(s) status-Wipe wash: OFF
                    CAN input signal(s) status-Rear window heater actual value: OFF
                    CAN input signal(s) status-Back-up light: OFF
                    CAN input signal(s) status-Actual value of windshield heater: OFF