Auto HVAC - 5G0 907 044 BP

Coding for Auto HVAC 5G0907044BP on Passat

5G0 907 044 BP :H04 / :1601
Coding: 12  02  01  24  20  24  10  01  11  15  50  0E  00  10  18  2A 
label: 5G0-907-044.clb
Faults: 0
# Byte 0 [12] / Binary: 00010010
bit 0-3
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 1 [02] / Binary: 00000010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 2 [01] / Binary: 00000001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 3 [24] / Binary: 00100100
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 4 [20] / Binary: 00100000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6-7
# Byte 5 [24] / Binary: 00100100
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 6 [10] / Binary: 00010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 7 [01] / Binary: 00000001
bit 0   Climate Modes active/displayed
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 8 [11] / Binary: 00010001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 9 [15] / Binary: 00010101
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-5
bit 6  
bit 7  
# Byte 10 [50] / Binary: 01010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 11 [0E] / Binary: 00001110
bit 0  
bit 1  
bit 2-3
bit 4   Frequency Shift for Blower Control Module active
bit 5  
bit 6   Blower Status Display in Auto-Mode active
bit 7  
# Byte 12 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 13 [10] / Binary: 00010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-5
bit 6  
bit 7  
# Byte 14 [18] / Binary: 00011000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 15 [2A] / Binary: 00101010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Address 08: Auto HVAC (J255)       Labels: 5G0-907-044.clb
   Part No SW: 5G0 907 044 BP    HW: 5G0 907 044 BP
   Component: Climatronic   H04 1601  
   Revision: 00001K10    
   Coding: 12020124202410011115500E0010182A
   Shop #: WSC 00015 115 08193
   ASAM Dataset: EV_ACClimaBHBVW37X 006142
   ROD: EV_ACClimaBHBVW37X_004_VW48.rod
   VCID: 76B6EC59584D8647053-8022
 
   Fresh Air Blower Front: 
 
   Refrigerant Pressure And Temperature Sender: 
 
   Air quality sensor: 
 
   Relative humidity sensor in fresh air intake duct: 
 
1 Fault Found:
1048835 - Functionality limited due to Engine Control Module 
          P1719 00 [008] - -
          Intermittent - Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 2
                    Reset counter: 128
                    Mileage: 3430 km
                    Date: 2017.01.01
                    Time: 01:22:48
 
                    Voltage terminal 30: 14.4 V
                    Auxiliary heater: in stages-Enabling for auxiliary heater operation: Enabling stage 3
                    Auxiliary heater: in stages-Act.value: 2
                    Auxiliary heater: in stages-Specified value: 3
                    Auxiliary heater: in stages-Specified value for control: 3