CAN Gateway 3C0 907 530 E coding and module information (3C0907530E)

Coding for CAN Gateway 3C0907530E / 3C0907951

3C0 907 530 E :H10 / :0080
Coding: FD  80  7F  4E  40  06  02  20  02 

label: 3C0-907-530-V2.clb
# Byte 0 [FD] / Binary: 11111101
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 1 [80] / Binary: 10000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 2 [7F] / Binary: 01111111
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 3 [4E] / Binary: 01001110
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 4 [40] / Binary: 01000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 5 [06] / Binary: 00000110
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 6 [02] / Binary: 00000010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 7 [20] / Binary: 00100000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 8 [02] / Binary: 00000010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Address 19: CAN Gateway        Labels:. 3C0-907-530-V2.clb
   Part No SW: 3C0 907 530 E    HW: 3C0 907 951 
   Component: J533__Gateway   H10 0080  
   Revision:   H10       Serial number: 1200P07905059A
   Coding: FD807F4E4006022002
   Shop #: WSC 05311 000 00000
   VCID: 230611D6E2DC84917C-8076
 
1 Fault Found:
01303 - Telephone Transceiver (R36) 
            004 - No Signal/Communication - Intermittent
             Freeze Frame:
                    Fault Status: 00100100
                    Fault Priority: 2
                    Fault Frequency: 245
                    Reset counter: 185
                    Mileage: 221391 km
                    Time Indication: 0
                    Date: 2021.09.22
                    Time: 16:45:16