Address 5F: Information Electr. (J794) Labels:| 5G0-035-MIB-STD2.clb Part No SW: 3Q0 035 824 A HW: 3Q0 035 824 A Component: MU-S--ER H24 0245 Serial number: VWZAZ2S0009982 Dataset Number: 5G0CV1v____ 0001 Coding: 02730200FF00000051110001000908001F0100C40120010047 Shop #: WSC 00028 028 00333 ASAM Dataset: EV_MUStd4CTSAT 001022 ROD: EV_MUStd4CTSAT_VW37.rod VCID: 2B55B2AB420539C946-807E Display and control head 1 for information electronics: Subsystem 1 - Part No SW: ----------- HW: ----------- Component: ------------- --- ---- Serial number: -------------------- 29 Faults Found: 1543 - Control Module Incorrectly Coded U1014 00 [00001001] - - Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 4 Fault Frequency: 1 Reset counter: 94 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:15 Voltage terminal 30: 12.1 V Byte_Coding_Condition-byte_0_condition: OK Byte_Coding_Condition-byte_1_condition: OK Byte_Coding_Condition-byte_10_condition: ERROR Byte_Coding_Condition-byte_11_condition: ERROR Byte_Coding_Condition-byte_12_condition: ERROR Byte_Coding_Condition-byte_13_condition: ERROR Byte_Coding_Condition-byte_14_condition: ERROR Byte_Coding_Condition-byte_15_condition: ERROR Byte_Coding_Condition-byte_16_condition: ERROR Byte_Coding_Condition-byte_17_condition: ERROR Byte_Coding_Condition-byte_18_condition: ERROR Byte_Coding_Condition-byte_19_condition: ERROR Byte_Coding_Condition-byte_2_condition: OK Byte_Coding_Condition-byte_20_condition: ERROR Byte_Coding_Condition-byte_21_condition: ERROR Byte_Coding_Condition-byte_22_condition: ERROR Byte_Coding_Condition-byte_23_condition: ERROR Byte_Coding_Condition-byte_24_condition: ERROR Byte_Coding_Condition-byte_25_condition: ERROR Byte_Coding_Condition-byte_26_condition: ERROR Byte_Coding_Condition-byte_27_condition: ERROR Byte_Coding_Condition-byte_3_condition: OK Byte_Coding_Condition-byte_4_condition: OK Byte_Coding_Condition-byte_5_condition: OK Byte_Coding_Condition-byte_6_condition: OK Byte_Coding_Condition-byte_7_condition: OK Byte_Coding_Condition-byte_8_condition: OK Byte_Coding_Condition-byte_9_condition: OK 0512 - Rear Right Bass Speaker B1067 13 [00001001] - Open Circuit [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 1 Reset counter: 94 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V 0517 - Front Right Bass Speaker B1062 13 [00001001] - Open Circuit [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 1 Reset counter: 94 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V 0522 - Front Left Bass Speaker B105F 13 [00001001] - Open Circuit [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 1 Reset counter: 94 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V 0527 - Rear Left Bass Speaker B1065 13 [00001001] - Open Circuit [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 1 Reset counter: 94 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V 0005 - Antenna Amplifier 1 for Radio B126D 13 [00001001] - Open Circuit Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 1 Reset counter: 94 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:15 Voltage terminal 30: 12.2 V Status of antenna 1 for radio-Antenna current: 0 mA Status of antenna 1 for radio-Connection between radio and antenna amplifier: electrically OK Status of antenna 1 for radio-Connection between antenna amplifier and antenna: electrically OK Status of antenna 1 for radio-Reception level antenna 1: 0 dBµV 0006 - Antenna Amplifier 2 for Radio B126E 13 [00001001] - Open Circuit Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 1 Reset counter: 94 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:15 Voltage terminal 30: 12.2 V Status of antenna 2 for radio-Antenna current: 0 mA Status of antenna 2 for radio-Connection between radio and antenna amplifier: electrically OK Status of antenna 2 for radio-Connection between antenna amplifier and antenna: electrically OK Status of antenna 2 for radio-Reception level antenna 2: 0 dBµV 1564 - Microphone 1 B129B 13 [00001001] - Open Circuit Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 4 Fault Frequency: 1 Reset counter: 94 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:15 Voltage terminal 30: 12.2 V 7169 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 59 Reset counter: 228 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7173 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 1 Reset counter: 94 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7175 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 99 Reset counter: 231 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7176 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 57 Reset counter: 228 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7177 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 58 Reset counter: 228 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7178 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 14 Reset counter: 209 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7180 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 57 Reset counter: 228 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7181 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 58 Reset counter: 228 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7182 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 58 Reset counter: 228 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7183 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 60 Reset counter: 228 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7185 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 52 Reset counter: 228 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7187 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 51 Reset counter: 228 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7191 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 172 Reset counter: 231 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7193 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 71 Reset counter: 230 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7194 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 3 Reset counter: 220 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7195 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 1 Reset counter: 94 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7201 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 73 Reset counter: 230 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7205 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 1 Reset counter: 189 Mileage: 144857 km Date: 2023.12.14 Time: 14:22:08 Voltage terminal 30: 11.3 V BAP-BAP_Function_ID: 02 7206 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 89 Reset counter: 230 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 7207 - Function Restricted due to Missing Message(s) U1111 00 [00001001] - - [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 6 Fault Frequency: 148 Reset counter: 231 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:18 Voltage terminal 30: 12.1 V BAP-BAP_Function_ID: 02 1637 - Interface for External Media U11B8 00 [00001001] - No Communications [New feature! Extended UDS fault detail is only supported by current gen. interfaces] Confirmed - Tested Since Memory Clear Freeze Frame: Fault Priority: 4 Fault Frequency: 1 Reset counter: 94 Mileage: 143349 km Date: 2023.11.03 Time: 17:29:16 Voltage terminal 30: 12.1 V Interface for external media: status-Status: Open circuit