Address 01: Engine (J623-DTRC) Labels: None
Part No SW: 05L 906 023 AA HW: 05L 907 309 C
Component: R4 2.0l TDI H30 0672
Revision: E3H30--- CVN: 0024DDC3746D3ABF66040229D51ED7E26604022943FB2DAA
Coding: 012500320324050930000000000000000000000000000000
Shop #: WSC 35110 377 00121
ASAM Dataset: EV_ECM20TDI01105L906023AA 007002
ROD: EV_ECM20TDI011_VN3S.rod
VCID: 678BB270CFE58363068-8032
VINID: 9E606AAAA8DBA9DA001401C124E091EE83
2 Faults Found:
2813 - Accelerator Position Sensor (G79)
P2122 00 [032] - Signal too Low
Intermittent - Not Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 9
Mileage: 1048 km
Date: 2021.07.20
Time: 16:03:21
Engine RPM: 0.00 /min
Normed load value: 0.0 %
Vehicle speed: 0 km/h
Coolant temperature: 36 °C
Intake air temperature: 33 °C
Ambient air pressure: 1000 mbar
Voltage terminal 30: 12.040 V
Unlearning counter according OBD: 9
Accelerator pedal travel: raw value: 0.00 %
Accelerator pedal: sensor voltage 1: 0.0 mV
Accelerator pedal: sensor voltage 2: 0.0 mV
Accelerator pedal: switch positions-Bits 0-7: 8
Starter control: Interlock- or P/N-signal: False result
Starter control: Interlock- or P/N-signal-Test_Program_B TRUE UBYTE: 0
Limitation: torque: 185.0 Nm
Control Module temperature: 29.5 °C
2815 - Accelerator Position Sensor 2 (G185)
P2127 00 [032] - Signal too Low
Intermittent - Not Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 9
Mileage: 1048 km
Date: 2021.07.20
Time: 16:03:21
Engine RPM: 0.00 /min
Normed load value: 0.0 %
Vehicle speed: 0 km/h
Coolant temperature: 36 °C
Intake air temperature: 33 °C
Ambient air pressure: 1000 mbar
Voltage terminal 30: 12.040 V
Unlearning counter according OBD: 9
Accelerator pedal travel: raw value: 0.00 %
Accelerator pedal: sensor voltage 1: 0.0 mV
Accelerator pedal: sensor voltage 2: 0.0 mV
Accelerator pedal: switch positions-Bits 0-7: 8
Starter control: Interlock- or P/N-signal: False result
Starter control: Interlock- or P/N-signal-Test_Program_B TRUE UBYTE: 0
Limitation: torque: 185.0 Nm
Control Module temperature: 29.5 °C
Readiness: 0 0 0 0 0