Auto HVAC - 5G0 907 044 AH

Coding for Auto HVAC 5G0907044AH on Passat

5G0 907 044 AH :H03 / :1001
Coding: 11  02  00  04  10  01  00  01  20  15  50  52  00  10  18  02 
label: 5G0-907-044.clb
Faults: 0
# Byte 0 [11] / Binary: 00010001
bit 0-3
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 1 [02] / Binary: 00000010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 2 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 3 [04] / Binary: 00000100
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 4 [10] / Binary: 00010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6-7
# Byte 5 [01] / Binary: 00000001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 6 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 7 [01] / Binary: 00000001
bit 0   Climate Modes active/displayed
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 8 [20] / Binary: 00100000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 9 [15] / Binary: 00010101
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-5
bit 6  
bit 7  
# Byte 10 [50] / Binary: 01010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 11 [52] / Binary: 01010010
bit 0  
bit 1  
bit 2-3
bit 4   Frequency Shift for Blower Control Module active
bit 5  
bit 6   Blower Status Display in Auto-Mode active
bit 7  
# Byte 12 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 13 [10] / Binary: 00010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-5
bit 6  
bit 7  
# Byte 14 [18] / Binary: 00011000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 15 [02] / Binary: 00000010
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Address 08: Auto HVAC (J255)       Labels:| 5G0-907-044.clb
   Part No SW: 5G0 907 044 AH    HW: 5G0 907 044 AH
   Component: Climatronic   H03 1001  
   Revision: 00001K10    
   Coding: 11020004100100012015505200101802
   Shop #: WSC 12345 678 02288
   ASAM Dataset: EV_ACClimaBHBVW37X 004131
   ROD: EV_ACClimaBHBVW37X_004_VW37.rod
   VCID: 6DD17FB6BC91F82CC3-8038
 
   Fresh Air Blower Front: 
 
   Refrigerant Pressure And Temperature Sender: 
 
   Air quality sensor: 
 
   Relative humidity sensor in fresh air intake duct: 
 
1 Fault Found:
459015 - Databus 
          U1121 00 [009] - Missing Message
          [New feature! Extended UDS fault detail is only supported by current gen. interfaces]
          Confirmed - Tested Since Memory Clear
             Freeze Frame:
                    Fault Status: 00000001
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 216
                    Mileage: 222823 km
                    Date: 2024.02.01
                    Time: 18:55:02