Address 5F: Information Electr. (J794) Labels:* None
Part No SW: 5NA 035 045 HW: 5NA 035 045
Component: MU-H-N-RW H51 0981
Serial number: A849L0HB001908
Coding: 0273000C0000000051110002001828001F0207F401200000DF
Shop #: WSC 35332 001 104857
ASAM Dataset: EV_MUHig4CGen2HBAS 001001
ROD: EV_MUHig4CGen2HBAS_VW37.rod
VCID: 75A20F9AD4480FEC04-8020
Operating And Display Unit 1:
Subsystem 1 - Part No SW: 5G6 919 606 HW: 5G6 919 606
Component: ABT_High-2 H35 9074
Serial number: VWZ6ZFS2960131
Data medium:
Subsystem 2 - Part No SW: V03 959 801 EC HW: -----------
Component: ROW 2017 --- 0062
Serial number: --------------------
Compact Disc Database:
Subsystem 3 - Part No SW: V03 959 800 EG HW: -----------
Component: Gracenote2 --- 4011
Serial number: --------------------
9 Faults Found:
1586 - invalid data record
B2005 00 [009] - -
[Control module (data record download) - invalid data record for speed shutoff thresholds]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 44
Mileage: 14793 km
Date: 2018.09.30
Time: 12:51:01
Voltage terminal 30: 13.8 V
1587 - invalid data record
B2005 00 [009] - -
[Control module (data record download) - invalid data record for language]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 44
Mileage: 14793 km
Date: 2018.09.30
Time: 12:51:01
Voltage terminal 30: 13.8 V
1588 - invalid data record
B2005 00 [009] - -
[Control module (data record download) - invalid data record for visible MMI system languages]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 44
Mileage: 14793 km
Date: 2018.09.30
Time: 12:51:01
Voltage terminal 30: 13.8 V
1589 - invalid data record
B2005 00 [009] - -
[Control module (data record download) - invalid data record for power management timer]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 44
Mileage: 14793 km
Date: 2018.09.30
Time: 12:51:01
Voltage terminal 30: 13.8 V
1595 - invalid data record
B2005 00 [009] - -
[Control module (data record download) - invalid data record for audio management HMI constants]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 44
Mileage: 14793 km
Date: 2018.09.30
Time: 12:51:01
Voltage terminal 30: 13.8 V
1652 - invalid data record
B2005 00 [009] - -
[Control module (data record download) - invalid data record for eco HMI]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 44
Mileage: 14793 km
Date: 2018.09.30
Time: 12:51:01
Voltage terminal 30: 13.8 V
1597 - Data Set Implausible
B2012 00 [009] - -
[Control module (data record download) - implausible data record for language]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 44
Mileage: 14793 km
Date: 2018.09.30
Time: 12:51:01
Voltage terminal 30: 13.8 V
1598 - Data Set Implausible
B2012 00 [009] - -
[Control module (data record download) - implausible data record for visible MMI system languages]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 44
Mileage: 14793 km
Date: 2018.09.30
Time: 12:51:01
Voltage terminal 30: 13.8 V
1555 - Check Software Version Management
B201A 00 [009] - -
[Check software version management]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 1
Reset counter: 44
Mileage: 14793 km
Date: 2018.09.30
Time: 12:51:06
Voltage terminal 30: 13.8 V
Status_Software_Version_Management-module_name: MMIBLite/MIBLite