Information Electr 565 035 021 C coding and module information (565035021C)
Coding for Information Electr 565035021C
/ 565035021
565 035 021 C
:H55 / :1311
Coding:
03
73
02
01
FF
00
00
00
41
11
12
04
00
88
02
33
2F
01
00
C4
01
20
05
00
BE
label: 3V0-035-MIB-HGH2.clb
# |
Byte 0 [03]
/ Binary: 00000011
|
bit 0-23 |
|
# |
Byte 1 [73]
/ Binary: 01110011
|
bit 0 |
☑
|
bit 1 |
☑
|
bit 2 |
☐
|
bit 3 |
☐
|
bit 4 |
☑
|
bit 5 |
☑
|
bit 6 |
☑
|
bit 7 |
☐
|
# |
Byte 2 [02]
/ Binary: 00000010
|
bit 0 |
☐
|
bit 1 |
☑
|
bit 2 |
☐
|
bit 3 |
☐
|
bit 4 |
☐
|
bit 5 |
☐
|
bit 6 |
☐
|
bit 7 |
☐
|
# |
Byte 3 [01]
/ Binary: 00000001
|
bit 0-7 |
|
# |
Byte 4 [FF]
/ Binary: 11111111
|
bit 0-31 |
|
# |
Byte 5 [00]
/ Binary: 00000000
|
bit 0 |
☐
|
bit 1 |
☐
|
bit 2 |
☐
|
bit 3 |
☐
|
bit 4 |
☐
|
bit 5 |
☐
|
bit 6 |
☐
|
bit 7 |
☐
|
# |
Byte 6 [00]
/ Binary: 00000000
|
bit 0 |
☐
|
bit 1 |
☐
|
bit 2 |
☐
|
bit 3 |
☐
|
bit 4 |
☐
|
bit 5 |
☐
|
bit 6 |
☐
|
bit 7 |
☐
|
# |
Byte 7 [00]
/ Binary: 00000000
|
bit 0 |
☐
|
bit 1 |
☐
|
bit 2 |
☐
|
bit 3 |
☐
|
bit 4 |
☐
|
bit 5 |
☐
|
bit 6 |
☐
|
bit 7 |
☐
|
# |
Byte 8 [41]
/ Binary: 01000001
|
bit 0 |
☑ Microphone 1 connected [PR-9IF]
|
bit 1 |
☐
|
bit 2 |
☐
|
bit 3 |
☐
|
bit 4 |
☐ AUX-IN Connection active [PR-UI2/UI4]
|
bit 5 |
☐
|
bit 6 |
☑
|
bit 7 |
☐
|
# |
Byte 9 [11]
/ Binary: 00010001
|
bit 0 |
☑
|
bit 1 |
☐
|
bit 2 |
☐
|
bit 3 |
☐
|
bit 4-7 |
|
# |
Byte 10 [12]
/ Binary: 00010010
|
bit 0 |
☐
|
bit 1 |
☑
|
bit 2 |
☐
|
bit 3 |
☐
|
bit 4-7 |
|
# |
Byte 11 [04]
/ Binary: 00000100
|
bit 0-7 |
|
# |
Byte 12 [00]
/ Binary: 00000000
|
bit 0-3 |
|
bit 4 |
☐
|
bit 5 |
☐
|
bit 6 |
☐
|
bit 7 |
☐
|
# |
Byte 13 [88]
/ Binary: 10001000
|
bit 0 |
☐
|
bit 1 |
☐
|
bit 2 |
☐
|
bit 3 |
☑ Radio Text Plus (RT+) active [STANDARD]
|
bit 4 |
☐
|
bit 5 |
☐
|
bit 6 |
☐
|
bit 7 |
☑ DAB Alarm Announcement active [PR-QV3]
|
# |
Byte 14 [02]
/ Binary: 00000010
|
bit 0 |
☐
|
bit 1 |
☑ AM-Band Hide Switch active
|
bit 2 |
☐
|
bit 3 |
☐ Multiple Entry Switch active
|
bit 4 |
☐
|
bit 5 |
☐
|
bit 6 |
☐
|
bit 7 |
☐
|
# |
Byte 15 [33]
/ Binary: 00110011
|
bit 0 |
☑
|
bit 1 |
☑
|
bit 2 |
☐
|
bit 3 |
☐
|
bit 4 |
☑ Telephone Module / Network Access Device (NAD) active [PR-9ZK]
|
bit 5 |
☑
|
bit 6 |
☐
|
bit 7 |
☐
|
# |
Byte 16 [2F]
/ Binary: 00101111
|
bit 0 |
☑
|
bit 1 |
☑
|
bit 2 |
☑
|
bit 3 |
☑
|
bit 4-5 |
|
bit 6 |
☐
|
bit 7 |
☐
|
# |
Byte 17 [01]
/ Binary: 00000001
|
bit 0-7 |
|
# |
Byte 18 [00]
/ Binary: 00000000
|
bit 0-7 |
|
# |
Byte 19 [C4]
/ Binary: 11000100
|
bit 0 |
☐
|
bit 1 |
☐
|
bit 2 |
☑
|
bit 3 |
☐
|
bit 4 |
☐
|
bit 5 |
☐
|
bit 6-7 |
|
# |
Byte 20 [01]
/ Binary: 00000001
|
bit 0 |
☑ Display 1 installed/connected
|
bit 1 |
☐
|
bit 2 |
☐
|
bit 3 |
☐
|
bit 4 |
☐
|
bit 5 |
☐
|
bit 6 |
☐
|
bit 7 |
☐
|
# |
Byte 21 [20]
/ Binary: 00100000
|
bit 0 |
☐
|
bit 1 |
☐
|
bit 2 |
☐
|
bit 3 |
☐
|
bit 4 |
☐
|
bit 5 |
☑ Messaging via MAP active
|
bit 6 |
☐
|
bit 7 |
☐
|
# |
Byte 22 [05]
/ Binary: 00000101
|
bit 0 |
☑ Instrument Cluster Graphics [STANDARD]
|
bit 1 |
☐
|
bit 2 |
☑
|
bit 3 |
☐
|
bit 4 |
☐
|
bit 5 |
☐
|
bit 6 |
☐
|
bit 7 |
☐
|
# |
Byte 23 [00]
/ Binary: 00000000
|
bit 0 |
☐
|
bit 1 |
☐
|
bit 2 |
☐
|
bit 3 |
☐
|
bit 4 |
☐
|
bit 5 |
☐
|
bit 6 |
☐
|
bit 7 |
☐
|
# |
Byte 24 [BE]
/ Binary: 10111110
|
bit 0 |
☐ Emergency Call active/installed
|
bit 1 |
☑ Speech Dialog System (SDS) active/installed [PR-QH1]
|
bit 2 |
☑ Navigation Function active/installed [PR-7UG]
|
bit 3 |
☑ WIFI Function active/installed [PR-9IF]
|
bit 4 |
☑ Multi Media Import (COPY) active
|
bit 5 |
☑ Multi Media Import (RIPPING) active
|
bit 6 |
☐ Traffic Sign Display (VZA) active
|
bit 7 |
☑ Predictive Route Data (PSD) active
|
Address 5F: Information Electr. (J794) Labels:| 3V0-035-MIB-HGH2.clb
Part No SW: 565 035 021 C HW: 565 035 021
Component: MU-H-LND-EU H55 1311
Serial number: A853H0JS067684 Dataset Number: V03935285QF 0001
Coding: 03730201FF00000041111204008802332F0100C401200500BE
Shop #: WSC 73430 790 00063
ASAM Dataset: EV_MUHig4CGen2HBAS 001001
ROD: EV_MUHig4CGen2HBAS_AU37.rod
VCID: 0E45AE2570D49BAAADF-805A
Display and control head 1 for information electronics:
Subsystem 1 - Part No SW: 5E0 919 606 D HW: 5E0 919 606 D
Component: ABT_High-2 H52 9130
Serial number: SKZ6ZHV2062633
Data carrier:
Subsystem 2 - Part No SW: V03 959 820 ML HW: -----------
Component: ECE 2024 --- 0350
Serial number: --------------------
Compact disc data bank:
Subsystem 3 - Part No SW: V03 959 800 EG HW: -----------
Component: Gracenote2 --- 1017
Serial number: --------------------
2 Faults Found:
1543 - Control Module Incorrectly Coded
U1014 00 [00001001] - -
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Fault Frequency: 1
Reset counter: 183
Mileage: 233210 km
Date: 2024.01.24
Time: 14:41:57
Voltage terminal 30: 12.1 V
Byte_Coding_Condition-byte_0_condition: OK
Byte_Coding_Condition-byte_1_condition: OK
Byte_Coding_Condition-byte_10_condition: ERROR
Byte_Coding_Condition-byte_11_condition: ERROR
Byte_Coding_Condition-byte_12_condition: ERROR
Byte_Coding_Condition-byte_13_condition: ERROR
Byte_Coding_Condition-byte_14_condition: ERROR
Byte_Coding_Condition-byte_15_condition: ERROR
Byte_Coding_Condition-byte_16_condition: ERROR
Byte_Coding_Condition-byte_17_condition: ERROR
Byte_Coding_Condition-byte_18_condition: ERROR
Byte_Coding_Condition-byte_19_condition: ERROR
Byte_Coding_Condition-byte_2_condition: OK
Byte_Coding_Condition-byte_20_condition: ERROR
Byte_Coding_Condition-byte_21_condition: ERROR
Byte_Coding_Condition-byte_22_condition: ERROR
Byte_Coding_Condition-byte_23_condition: ERROR
Byte_Coding_Condition-byte_24_condition: ERROR
Byte_Coding_Condition-byte_25_condition: ERROR
Byte_Coding_Condition-byte_26_condition: ERROR
Byte_Coding_Condition-byte_27_condition: ERROR
Byte_Coding_Condition-byte_3_condition: OK
Byte_Coding_Condition-byte_4_condition: OK
Byte_Coding_Condition-byte_5_condition: OK
Byte_Coding_Condition-byte_6_condition: OK
Byte_Coding_Condition-byte_7_condition: OK
Byte_Coding_Condition-byte_8_condition: OK
Byte_Coding_Condition-byte_9_condition: OK
1555 - Check Software Version Management
B201A 00 [00001001] - -
[Check software version management]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 11
Reset counter: 183
Voltage terminal 30: 12.1 V
Status_Software_Version_Management-module_name: MDUK623/Main