Information Electr - 561 035 150

Coding for Information Electr 561035150 on Passat NMS

561 035 150 :857 / :6495
Coding: 02  14  01  00  BE  00  00  00  41  11  00  01  00  10  00  00  1F  00  00  D4  00  00  01  00  00 
label: 5G0-035-MIB-ENT2.clb
Faults: 1
Fault 1537: Напряжение электропитания
: слишком низкое напряжение
# Byte 0 [02] / Binary: 00000010
bit 0-23
# Byte 1 [14] / Binary: 00010100
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 2 [01] / Binary: 00000001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 3 [00] / Binary: 00000000
bit 0-7
# Byte 4 [BE] / Binary: 10111110
bit 0-31
# Byte 5 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 6 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 7 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 8 [41] / Binary: 01000001
bit 0   Microphone 1 connected [PR-9ZX]
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6   VDA Low Frequency Input active
bit 7  
# Byte 9 [11] / Binary: 00010001
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 10 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 11 [01] / Binary: 00000001
bit 0-7
# Byte 12 [00] / Binary: 00000000
bit 0-3
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 13 [10] / Binary: 00010000
bit 0   RDS HMI Switch active
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7   DAB Alarm Announcement active [PR-QV3]
# Byte 14 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4   RDS Deactivation active
bit 5   AF Deactivation active
bit 6  
bit 7  
# Byte 15 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 16 [1F] / Binary: 00011111
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-5
bit 6  
bit 7  
# Byte 17 [00] / Binary: 00000000
bit 0-7
# Byte 18 [00] / Binary: 00000000
bit 0-7
# Byte 19 [D4] / Binary: 11010100
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6-7
# Byte 20 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 21 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 22 [01] / Binary: 00000001
bit 0   Instrument Cluster Graphics [STANDARD]
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 23 [00] / Binary: 00000000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
# Byte 24 [00] / Binary: 00000000
bit 0   Emergency Call active/installed
bit 1  
bit 2  
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Адрес 5F:  Электронная информационная система 1 (J794)       Файл QML:| 5G0-035-MIB-ENT2.clb
   Номер детали ПО: 561 035 150     АО: 561 035 150 
   Компонент: MU-E--US      857 6495  
   Заводской номер: 13011600010754
   Кодировка: 02140100BE00000041110001001000001F0000D40000010000
   Мастерская #: WSC 09003 957 00200
   Метка файла ASAM/ODX: EV_MUEnt4CGen2LGE 001025
   ODX: EV_MUEnt4CGen2LGE_VW26.odx
     
 
1 неисправность:
1537 - Напряжение электропитания 
          U1011 00 [008] - слишком низкое напряжение
          [Supply voltage - lower limit value not reached]
          Непостоянно - Подтверждено - протестировано после удаления записей
             Стоп-кадр:
                    Биты состояния: 00000001
                    Приоритетность: 3
                    Счётчик возникновения ошибки: 1
                    Индекс забывания: 25
                    Пробег: 108399 km
                    Дата: 2022.07.18
                    Время: 11:58:55
 
                    Напряжение клеммы 30: 9.0 V