Address 77: Telephone (J412) Labels:| 3C8-035-730-A.clb
Part No SW: 3C8 035 730 C HW: 3C8 035 730 C
Component: Telefon 012 0822
Revision: -------- Serial number: 35909603550656
Coding: 020100000000000000000000
Shop #: WSC 00015 115 00000
ASAM Dataset: EV_UHVPremi A02705
ROD: EV_UHVPremi_A02.rod
VCID: 23455A8B2AD5F1917C-8076
2 Faults Found:
13893632 - Function Restricted due to Insufficient Voltage
U1400 00 [008] - -
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 66
Reset counter: 40
Mileage: 453921 km
Date: 2022.06.19
Time: 00:00:52
13635840 - Supply voltage
U1011 00 [008] - Voltage too Low
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 3
Fault Frequency: 4
Reset counter: 40
Mileage: 453921 km
Date: 2022.06.19
Time: 01:05:59
End-------------------------(Elapsed Time: 09:49)--------------------------