CAN Gateway 7N0 907 530 BL coding and module information (7N0907530BL)

Coding for CAN Gateway 7N0907530BL / 7N0907530AN

7N0 907 530 BL :H56 / :1682
Coding: 35  10  22 

label: 7N0-907-530-V2.clb
# Byte 0 [35] / Binary: 00110101
bit 0-7
# Byte 1 [10] / Binary: 00010000
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 2 [22] / Binary: 00100010
bit 0   Right Hand Drive (RHD)
bit 1   4 Doors (or more)
bit 2   Immobilizer via CAN-Comfort (instead of CAN-Instruments)
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Address 19: CAN Gateway (J533)       Labels:. 7N0-907-530-V2.clb
   Part No SW: 7N0 907 530 BL    HW: 7N0 907 530 AN
   Component: J533  Gateway H56 1682  
   Revision:   H56       Serial number: 07061703010470
   Coding: 351022
   Shop #: WSC 00066 790 00166
   VCID: 7BFFAA2EFAE5695114-802E
 
6 Faults Found:
01309 - Power Steering Control Module (J500) 
            004 - No Signal/Communication
             Freeze Frame:
                    Fault Status: 01110100
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 99
                    Mileage: 169331 km
                    Time Indication: 0
                    Date: 2017.01.19
                    Time: 00:01:16
 
01044 - Control Module Incorrectly Coded 
            000 - -
             Freeze Frame:
                    Fault Status: 01100000
                    Fault Priority: 1
                    Fault Frequency: 254
                    Reset counter: 255
                    Mileage: 169331 km
                    Time Indication: 0
                    Date: 2017.01.19
                    Time: 00:00:07
 
03406 - Control Module for Battery Monitoring 
            004 - No Signal/Communication
             Freeze Frame:
                    Fault Status: 01100100
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 99
                    Mileage: 169331 km
                    Time Indication: 0
                    Date: 2017.01.19
                    Time: 00:02:15
 
02001 - Data-Bus Automatic Distance Regulation 
            004 - No Signal/Communication
             Freeze Frame:
                    Fault Status: 01110100
                    Fault Priority: 1
                    Fault Frequency: 1
                    Reset counter: 99
                    Mileage: 169331 km
                    Time Indication: 0
                    Date: 2017.01.19
                    Time: 00:01:16
 
03981 - Pause recommendation not available 
            000 - -
             Freeze Frame:
                    Fault Status: 01110000
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 149
                    Mileage: 169682 km
                    Time Indication: 0
                    Date: 2017.02.08
                    Time: 21:35:33
 
03158 - Control Module for Information Electronics 1 (J794) 
            004 - No Signal/Communication
             Freeze Frame:
                    Fault Status: 01110100
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 99
                    Mileage: 169331 km
                    Time Indication: 0
                    Date: 2017.01.19
                    Time: 00:00:10