CAN Gateway - 7N0 907 530 C

Coding for CAN Gateway 7N0907530C on Yeti

7N0 907 530 C :H37 / :0614
Coding: 35  63  02 
label: 7N0-907-530-V2.clb
Faults: 2
Fault 00381: Databus Instrument Cluster
: No Signal/Communication
# Byte 0 [35] / Binary: 00110101
bit 0-7
# Byte 1 [63] / Binary: 01100011
bit 0  
bit 1  
bit 2  
bit 3  
bit 4-7
# Byte 2 [02] / Binary: 00000010
bit 0   Right Hand Drive (RHD)
bit 1   4 Doors (or more)
bit 2   Immobilizer via CAN-Comfort (instead of CAN-Instruments)
bit 3  
bit 4  
bit 5  
bit 6  
bit 7  
Address 19: CAN Gateway (J533)       Labels:. 7N0-907-530-V2.clb
   Part No SW: 7N0 907 530 C    HW: 1K0 907 951 
   Component: J533  Gateway H37 0614  
   Revision:   H37       Serial number: 160511F6000808
   Coding: 356302
   Shop #: WSC 33361 790 00102
   VCID: 306FA5C763235A04B3-8064
 
2 Faults Found:
00381 - Databus Instrument Cluster 
            004 - No Signal/Communication - Intermittent
             Freeze Frame:
                    Fault Status: 00100100
                    Fault Priority: 1
                    Fault Frequency: 19
                    Reset counter: 76
                    Time Indication: 0
 
00474 - Control Module for Immobilizer 
            004 - No Signal/Communication - Intermittent
             Freeze Frame:
                    Fault Status: 00110100
                    Fault Priority: 2
                    Fault Frequency: 1
                    Reset counter: 76
                    Time Indication: 0