Address 8C: HV Battery (J840) Labels: None
Part No SW: 4M0 915 233 AA HW: 4M0 915 233 J
Component: BMC_PHEV_BYB H15 0273
Dataset Number: 4M0909107A 0001
ASAM Dataset: EV_BECM0842071 001004
ROD: EV_BECM0842071_AU49.rod
VCID: 6A8DC2B52CFC178A917-803E
Battery interrupt switch:
Subsystem 1 - Part No SW: 4M0 915 253 H HW: 4M0 915 253 H
Component: J990 SFT426D0 H22 0303
Cell module control module 1:
Subsystem 2 - Part No SW: 4M0 915 115 C HW: 4M0 915 115 A
H08 0107
Cell module control module 2:
Subsystem 3 - Part No SW: 4M0 915 115 C HW: 4M0 915 115 A
H08 0107
Cell module control module 3:
Subsystem 4 - Part No SW: 4M0 915 115 C HW: 4M0 915 115 A
H08 0107
Cell module control module 4:
Subsystem 5 - Part No SW: 4M0 915 115 C HW: 4M0 915 115 A
H08 0107
Cell module control module 5:
Subsystem 6 - Part No SW: 4M0 915 115 C HW: 4M0 915 115 A
H08 0107
Cell module control module 6:
Subsystem 7 - Part No SW: 4M0 915 115 C HW: 4M0 915 115 A
H08 0107
Cell module control module 7:
Subsystem 8 - Part No SW: 4M0 915 115 C HW: 4M0 915 115 A
H08 0107
Cell module control module 8:
Subsystem 9 - Part No SW: 4M0 915 115 C HW: 4M0 915 115 A
H08 0107
Cell module control module 9:
Subsystem 10 - Part No SW: 4M0 915 115 C HW: 4M0 915 115 A
H08 0107
Cell module control module 10:
Subsystem 11 - Part No SW: 4M0 915 115 C HW: 4M0 915 115 A
H08 0107
Cell module control module 11:
Subsystem 12 - Part No SW: 4M0 915 115 C HW: 4M0 915 115 A
H08 0107
Cell module control module 12:
Subsystem 13 - Part No SW: 4M0 915 115 C HW: 4M0 915 115 A
H08 0107
Cell module control module 13:
Subsystem 14 - Part No SW: 4M0 915 115 C HW: 4M0 915 115 A
H08 0107
Cell module control module 14:
Subsystem 15 - Part No SW: 4M0 915 115 C HW: 4M0 915 115 A
H08 0107
1 Fault Found:
49186 - Position Sensor for Battery Charger Coupling Lock
P0D9E 00 [00100000] - Electrical Malfunction
Intermittent - Not Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 2
Fault Frequency: 1
Mileage: 64338 km
Date: 2024.01.12
Time: 23:27:41
Unlearning counter according OBD: 38
High-volt. battery mode: spec. value: Standby-mode
Mode HV battery actual value: Standby-mode
H-V battery voltage: 321.20 V
Voltage in H-V system-Voltage of hybrid battery after protection: 15.00 V
Current of H-V / hybrid battery: -0.00 A
Battery temperature: 25 C
Battery charge level: 69 %
Terminal 30 power supply: 12.40 V
Voltage terminal 30C: 12.20 V
Terminal 15 status via CAN: OFF
Power reduction status: not active
Malfunction Indicator Lamp-Start request: not active
Service Disconnect: Status: connected
Pilot line: closed
Status of voltage freedom: High voltage power off not recognized
Crash signal: not active
Protection of posit. terminal of high voltage / hybrid battery: Open
Protection of neg. terminal of high voltage / hybrid battery: Open
Status pre-loader: Open
HV battery: cool. level requirement: invalid
Pump for HV battery coolant: specified speed value: 12.00 %
Pump for HV battery coolant: status: No malfunction
HV battery positive terminal insulation resistance-Status: Initialization
HV battery positive terminal insulation resistance: 10000 kOhm
HV battery minus terminal insulation resistance-Status: Initialization
HV battery minus terminal insulation resistance: 10000 kOhm
Entire HV system positive terminal insulation resistance-Status: Initialization
Entire HV system positive terminal insulation resistance: 20470 kOhm
Entire HV system minus terminal insulation resistance-Status: Initialization
Entire HV system minus terminal insulation resistance: 20470 kOhm
maximum voltage for battery cells-Index 1: 0
maximum voltage for battery cells-Value: 3.833 V
minimum voltage for battery cells-Index 1: 0
minimum voltage for battery cells-Value: 3.829 V
Highest measured temperature-Temperature sensor: 0
Highest measured temperature-Value: 26 C
Lowest measured temperature-Temperature sensor: 0
Lowest measured temperature-Value: 22 C
Coolant temperature of H-V / hybrid battery-Intake: -100 C
Coolant temperature of H-V / hybrid battery-Exhaust: 19 C
Maximum charge level-Index 1: 0
Maximum charge level-Value: 69 %
Minimum charge level-Index 1: 0
Minimum charge level-Value: 68 %
Dynamic limit for charge current-Limit for charge current: 280 A
Predictive limit for charge current-Limit for charge current: 51 A
Dynamic limit for discharge current-Limit for discharge current: 360 A
Predictive limit for discharge current-Limit for discharge current: 150 A
Maximum charging voltage: 348.60 V
Minimum discharge voltage: 235.20 V
Minimum dynamic charging voltage: 338.20 V
Minimum predictive charging voltage: 325.30 V
Minimum dynamic discharge voltage: 299.50 V
Minimum predictive discharge voltage: 310.90 V