Auto HVAC - 3AA 907 044 AG
Coding for Auto HVAC 3AA907044AG on Passat B7
3AA 907 044 AG
:H03 /
:0303
Coding: 00 14 00 48 03
Coding: 00 14 00 48 03
label:
5K0-907-044.clb
- Show complete log #422 for Passat B7 2013 (22 control modules, scanned at 20.07.2022)
- Show more logs for Volkswagen Passat B7 2013
- Show more items 3AA 907 044 AG
Faults: 0
Fault 9481746: High Pressure Sensor
: Short to Plus
: Short to Plus
Fault 9481748: High Pressure Sensor
: Open or Short to Ground
: Open or Short to Ground
Fault 9480469: Control Circuit for A/C Compressor
: Open or Short to Plus
: Open or Short to Plus
Fault 13635840: Supply voltage
: Voltage too Low
: Voltage too Low
| # |
Byte 0 [00]
/ Binary: 00000000 |
|---|---|
| bit 0-5 | |
| bit 6 | |
| bit 7 |
| # |
Byte 1 [14]
/ Binary: 00010100 |
|---|---|
| bit 0-2 | |
| bit 3 | Extended Display Temperature Range active |
| bit 4 | Function Light Dimming via Light Sensor active |
| bit 5 | |
| bit 6 | |
| bit 7 |
| # |
Byte 2 [00]
/ Binary: 00000000 |
|---|---|
| bit 0 | |
| bit 1 | |
| bit 2 | |
| bit 3-5 | |
| bit 6 | |
| bit 7 |
| # |
Byte 3 [48]
/ Binary: 01001000 |
|---|---|
| bit 0 | |
| bit 1 | |
| bit 2 | |
| bit 3 | |
| bit 4-6 | |
| bit 7 | Blower/Display Logic for absolute Blower Voltage without Blower Stage Display |
| # |
Byte 4 [03]
/ Binary: 00000011 |
|---|---|
| bit 0 | |
| bit 1-3 | |
| bit 4 | |
| bit 5 | |
| bit 6 | Compressor Shutoff via Humidity Sensor active |
| bit 7 |
Address 08: Auto HVAC (J255) Labels:| 5K0-907-044.clb
Part No SW: 3AA 907 044 AG HW: 3AA 907 044 AG
Component: Climatronic H03 0303
Revision: 00001K02
Coding: 0014004803
Shop #: WSC 00015 115 00000
ASAM Dataset: EV_Climatronic A01010
ROD: EV_ClimaAutoBasis_VW36.rod (VIN: N/A)
VCID: 75E154D3D4C13F2162-8020
10 Faults Found:
13701376 - Function Restricted due to Missing Message(s)
U1111 00 [009] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 44
Reset counter: 0
Mileage: 453921 km
Date: 2022.06.05
Time: 00:17:40
13701888 - Function Restriction due to Faults in Other Modules
U1113 00 [008] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 1
Reset counter: 40
Mileage: 453920 km
Date: 2022.06.05
Time: 21:09:17
13701392 - Function Restricted due to Missing Message(s)
U1111 00 [008] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 4
Reset counter: 40
Mileage: 453921 km
Date: 2022.07.11
Time: 07:48:49
13701968 - Function Restriction due to Faults in Other Modules
U1113 00 [009] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 38
Reset counter: 0
Mileage: 453920 km
Date: 2022.06.05
Time: 21:09:17
13701504 - Function Restricted due to Missing Message(s)
U1111 00 [008] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 1
Reset counter: 40
Mileage: 453921 km
Date: 2022.07.12
Time: 00:00:03
13701536 - Function Restricted due to Missing Message(s)
U1111 00 [009] - -
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 6
Fault Frequency: 12
Reset counter: 0
Mileage: 453921 km
Date: 2022.07.12
Time: 00:00:03
9481746 - High Pressure Sensor
B10AE 12 [009] - Short to Plus
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 0
Mileage: 453921 km
Date: 2022.07.20
Time: 00:00:29
9481748 - High Pressure Sensor
B10AE 14 [008] - Open or Short to Ground
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 40
Mileage: 453920 km
Date: 2022.06.05
Time: 21:09:09
9480469 - Control Circuit for A/C Compressor
B10A9 15 [009] - Open or Short to Plus
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 0
Mileage: 453920 km
Date: 2022.06.05
Time: 21:09:10
13635840 - Supply voltage
U1011 00 [008] - Voltage too Low
[New feature! Extended UDS fault detail is only supported by current gen. interfaces]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 1
Fault Frequency: 2
Reset counter: 40
Mileage: 453921 km
Date: 2022.07.11
Time: 02:11:44