Address 13: Auto Dist. Reg (J428) Labels:* None
Part No SW: 4M0 907 561 Q HW: 4K0 907 561
Component: LRR4R H12 0492
Dataset Number: 4M0909863AA 0002
Coding: 5765FF5C58082C00010380200000003E4A1246494401409E21
Shop #: WSC 31414 039 00001
ASAM Dataset: EV_ACCBOSCHAU65X 002026
ROD: EV_ACCBOSCHAU65X_AU73.rod
VCID: 3E253EE500F44B2A1DF-806A
7 Faults Found:
2342 - Databus
U1123 00 [00001001] - Received Error Message
[FAULT_ACA_QF_STATUS_DISPLAY_ERROR]
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 68
Reset counter: 91
Mileage: 63064 km
Date: 2023.12.12
Time: 14:56:58
Control Module temperature: 23 C
Voltage terminal 15: 12.9 V
Vehicle speed: 0.00 m/s
Longitudinal acceleration: 0.00 m/s
Adaptive distance regulation: status: ACC_irreversible error
Steering_angle-Data: -3.600
Yaw_rate-Data: 0.000 rad/s
adjustment_calculation: OFF
Misalignment angle: horiz: -0.589
Misalignment angle: horiz: fast algorithm: -0.772
Congestion pilot: status: OFF
Outside temperature: 14.50 C
Sensor blindness: radar: no blindness detected
2344 - Databus
U1123 00 [00001000] - Received Error Message
[FAULT_CAMERA_DIRT_OBJ]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 1
Reset counter: 118
Mileage: 63653 km
Date: 2024.01.09
Time: 09:40:31
Control Module temperature: 9 C
Voltage terminal 15: 15.0 V
Vehicle speed: 6.63 m/s
Longitudinal acceleration: 0.69 m/s
Adaptive distance regulation: status: ACC_StandBy
Steering_angle-Data: -144.800
Yaw_rate-Data: -5.466 rad/s
adjustment_calculation: On
Misalignment angle: horiz: -0.539
Misalignment angle: horiz: fast algorithm: -0.689
Congestion pilot: status: OFF
Outside temperature: -4.00 C
Sensor blindness: radar: no blindness detected
2343 - Databus
U1123 00 [00001000] - Received Error Message
[FAULT_CAMERA_DIRT_PEDEST]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 1
Reset counter: 118
Mileage: 63653 km
Date: 2024.01.09
Time: 09:40:31
Control Module temperature: 9 C
Voltage terminal 15: 15.0 V
Vehicle speed: 6.63 m/s
Longitudinal acceleration: 0.69 m/s
Adaptive distance regulation: status: ACC_StandBy
Steering_angle-Data: -144.800
Yaw_rate-Data: -5.466 rad/s
adjustment_calculation: On
Misalignment angle: horiz: -0.539
Misalignment angle: horiz: fast algorithm: -0.689
Congestion pilot: status: OFF
Outside temperature: -4.00 C
Sensor blindness: radar: no blindness detected
1289 - Heating Element for ACC Radar Sensor
C1317 01 [00001001] - Electrical Failure
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Fault Frequency: 63
Reset counter: 91
Mileage: 63093 km
Date: 2023.12.14
Time: 17:47:58
Control Module temperature: 20 C
Voltage terminal 15: 14.7 V
Vehicle speed: 15.15 m/s
Longitudinal acceleration: 0.13 m/s
Adaptive distance regulation: status: ACC_StandBy
Steering_angle-Data: 0.300
Yaw_rate-Data: -0.007 rad/s
adjustment_calculation: On
Misalignment angle: horiz: -0.569
Misalignment angle: horiz: fast algorithm: -0.443
Congestion pilot: status: OFF
Outside temperature: 5.00 C
Sensor blindness: radar: no blindness detected
2314 - Databus
U1121 00 [00001000] - Missing Message
[FAULT_TIMEOUT_AIRBAG_05]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Fault Frequency: 1
Reset counter: 110
Mileage: 63064 km
Date: 2023.12.12
Time: 14:56:58
Control Module temperature: 23 C
Voltage terminal 15: 12.9 V
Vehicle speed: 0.00 m/s
Longitudinal acceleration: 0.00 m/s
Adaptive distance regulation: status: ACC_irreversible error
Steering_angle-Data: -3.600
Yaw_rate-Data: 0.000 rad/s
adjustment_calculation: OFF
Misalignment angle: horiz: -0.589
Misalignment angle: horiz: fast algorithm: -0.772
Congestion pilot: status: OFF
Outside temperature: 14.50 C
Sensor blindness: radar: no blindness detected
1068 - Databus
U1121 00 [00001000] - Missing Message
[FAULT_TIMEOUT_SARA_06]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 4
Fault Frequency: 1
Reset counter: 110
Mileage: 63064 km
Date: 2023.12.12
Time: 14:56:58
Control Module temperature: 23 C
Voltage terminal 15: 12.9 V
Vehicle speed: 0.00 m/s
Longitudinal acceleration: 0.00 m/s
Adaptive distance regulation: status: ACC_irreversible error
Steering_angle-Data: -3.600
Yaw_rate-Data: 0.000 rad/s
adjustment_calculation: OFF
Misalignment angle: horiz: -0.589
Misalignment angle: horiz: fast algorithm: -0.772
Congestion pilot: status: OFF
Outside temperature: 14.50 C
Sensor blindness: radar: no blindness detected
1135 - Databus
U1121 00 [00001000] - Missing Message
[FAULT_TIMEOUT_SWA_HEADER]
Intermittent - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Priority: 6
Fault Frequency: 1
Reset counter: 110
Mileage: 63064 km
Date: 2023.12.12
Time: 14:56:58
Control Module temperature: 23 C
Voltage terminal 15: 12.9 V
Vehicle speed: 0.00 m/s
Longitudinal acceleration: 0.00 m/s
Adaptive distance regulation: status: ACC_irreversible error
Steering_angle-Data: -3.600
Yaw_rate-Data: 0.000 rad/s
adjustment_calculation: OFF
Misalignment angle: horiz: -0.589
Misalignment angle: horiz: fast algorithm: -0.772
Congestion pilot: status: OFF
Outside temperature: 14.50 C
Sensor blindness: radar: no blindness detected